User's Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd
14
Set
AT+PARI=[para]
+OK:success
+ERR=[NUM]
:error
Parameter
para(ASCII)
Description
0
5 data bit
1
6 data bit
2
7 data bit
3
8 data bit
Note
Restart to take effect, save when power off
For example,
AT+PARI=0
5.4.9 AT+ROLE bluetooth role
Command
Response
Inquiry
AT+ROLE?
+OK=[para]
Set
AT+ROLE =[para]
+OK:success
+ERR=[NUM]:error
Parameter
Para(ASCII)
Description
0
Slave(default)
1
Master
2
Observer
3
Salve and master as one
Note
Restart to take effect, save when power off
5.4.10 AT+DEVMANUF devise manufacturer
Command
Response
Inquiry
AT+DEVMANUF?
+OK=[para]
Set
AT+DEVMANUF =[para]
+OK:success
+ERR=[NUM]:error
Parameter
para( string): MANUF name
Default:CDEBYTE;
Note
1. Restart to take effect, save when power off
2. Maximum string length is 32bytes
5.4.11 AT+ADV enable advertising
Command
Response