User's Manual

Copyright ©20122020Chengdu Ebyte Electronic Technology Co.,Ltd
16
5.4.14 AT+IBCNUUID iBeacon UUID command
Command
Response
Inquiry
AT+IBCNUUID?
+OK=[para1]
Set
AT+IBCNUUID=[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(HEX)16 bit UUID
Note
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
save when power off
2. The slave or master-slave integrated supports broadcasting, other roles can still be configured;
For example,
Set iBeacon UUID as “FDA50693A4E24FB1AFCFC6EB07647825”
41 54 2B 49 42 43 4E 55 55 49 44 3DFDA50693A4E24FB1AFCFC6EB07647825
5.4.15 AT+MAJOR iBeacon Major command
Command
Response
Inquiry
AT+MAJOR?
+OK=[para]
Set
AT+MAJOR=[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(HEX) 0X0001-0XFFFF
default
Note
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
save when power off;
2. Only the slave device supports broadcasting, other roles can still be configured;
5.4.16 AT+MINOR iBeacon Minor command
Command
Response
Inquiry
AT+Minor?
+OK=[para]
Set
AT+Minor=[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(ACSII) 0X0001-0XFFFF
default
Note
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
save when power off;
2. Only the slave device supports broadcasting, other roles can still be configured;