User's Manual

Copyright ©20122020Chengdu Ebyte Electronic Technology Co.,Ltd
20
5.4.26 AT+SCANINTV scan interval
Command
Response
Inquiry
AT+SCANINTV?
+OK=[para]
Set
AT+SCANINTV=[para]
+OKsuccess
+ERR=[NUM]
error
Parameter
para(ASCII):20~6000
default100
Note
1. Take effect immediately, save when power off
2. The scanning interval is not less than the scanning window
3. The slave does not support it, but it can still be set
For example,
AT+SCANINTV=120
Scan interval120*0.625 = 75ms
5.4.27AT+SCANWND scan window
Command
Response
Inquiry
AT+SCANWND?
+OK=[para]
Set
AT+SCANWND=[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(ASCII): 20~65535
default80
Note
1. Take effect immediately, save when power off
2. The scanning interval is not less than the scanning window
3. The slave does not support it, but it can still be set
For example,
AT+SCANWND=20
Scan window20*0.625 = 12.5ms
5.4.28 AT+TRANMD master transmission mode
Command
Response
Inquiry
AT+TRANMD?
+OK=[para]
Set
AT+ TRANMD =[ para]
+OKsuccess
+ERR=[NUM]error
Parameter
paraASCII
description
0
Not transparent transmissiondefault
1
Transparent transmission
Note
1 Take effect immediately, save when power off