User's Manual

Copyright ©20122020Chengdu Ebyte Electronic Technology Co.,Ltd
27
Other parameters are the default configuration.
6.2.1 Data transparent transmission
1. Power on the module. Enable logmsg printing for master and slave (at+logmsg=1);
2. Set the module to transparent transmission mode (AT+TRANMD=1).
3. After the host is successfully connected, it will print "sta: connecte 0 616263646564"; the slave will print sta: connecte 0
616263646566". The LINK pin is high. As shown below, the host is automatically connected and printed: The slave is powered on The
automatic connection printing is shown in the figure. The value before the MAC address in the host print information is the slave
handle in the host, and the first byte of the format transmission comes from this.
The master auto connects and prints once powered on
The slave auto connects and prints once powered on
1. The master sends data “0123456789” to the slavethe slave receives “0123456789”, as shown below
2. The slave sends data “abcdefghijk” to the masterthe master receives “abcdefghijk”, as shown below