2 Specification and Parameter
2.1 Limit parameter
Main parameter
Performance
Remark
Min
Power supplyV
0
Over 3.6V damages module
Blocking powerdBm
-
Chance of is slim when modules are used in short
distance
Operating temperature(℃)
-40
Industrial grade
2.2 Operating parameter
Main parameter
Performance
Remark
Min
Typ
Max
Operating voltageV
2.1
3.3
3.6
≥3.3V ensures performance
Communication levelV
-
3.3
-
5V will damage modules
Operating temperature
-40
-
+65
Industrial design
Operating frequencyMHz
2402
-
2480
For ISM band
Power
consumption
Tx currentmA
-
4.0
-
Default parameter
Rx currentmA
-
-
-
-
Sleep currentμA
-
1
-
Default parameter
Receiving sensitivitydBm
-94
Air data rate 1Mbps
Sleep advertising current(default)
9.44
Unit uA, default advertising gap 1S
Wake-up advertising current (default)
403
UnituA, default advertising gap 1s
Sleep without advertising current (default)
2
UnituA, default connection gap 500ms