Set:AT+CONTO=[para]
+OK:success
+ERR=[NUM]:error
Example:500
500*10ms=5s
Description :The next connection takes effect, save when power off
5.19 Disconnect present connection
Command
Respond
Parameter
Request:AT+DISCON
+OK
None
Description: Be effective at once
5.20 Request present connection status
Command
Respond
Parameter
Request:AT+CONSTA?
+OK=[para]
Para:
Connected:Connection setup
Disconnect:Connection break
Description: Be effective at once
5.21 Request local MAC address
Command
Respond
Parameter
Request:AT+MAC?
+OK=[para]
Para:MAC address
Example:F0E1D2C3B4A5
5.22 Request MAC address of connected devices
Command
Respond
Parameter
Request:AT+PEERMAC?
+OK=[para]
Para:MAC address
Example:F0E1D2C3B4A5
Description: Be effective at once
5.23 Read MAC binding status, turn MAC binding on and off
Command
Respond
Parameter
Request:AT+BOND?
+OK=[para]
Para:0,1 ASCII
0:Bind off
1:Bind on
Set:AT+BOND=[para]
+OK:success
+ERR=[NUM]:error