User's Manual

Chengdu Ebyte Electronic Technology Co., Ltd E104-BT05 User Manual
Copyright ©20122019Chengdu Ebyte Electronic Technology Co.,Ltd
18
SetAT+CONTO=[para]
+OKsuccess
+ERR=[NUM]error
Example500
500*10ms=5s
Description :The next connection takes effect, save when power off
5.19 Disconnect present connection
Command
Respond
Parameter
RequestAT+DISCON
+OK
None
Description: Be effective at once
5.20 Request present connection status
Command
Respond
Parameter
RequestAT+CONSTA?
+OK=[para]
Para:
ConnectedConnection setup
DisconnectConnection break
Description: Be effective at once
5.21 Request local MAC address
Command
Respond
Parameter
RequestAT+MAC?
+OK=[para]
Para:MAC address
ExampleF0E1D2C3B4A5
5.22 Request MAC address of connected devices
Command
Respond
Parameter
RequestAT+PEERMAC?
+OK=[para]
Para:MAC address
ExampleF0E1D2C3B4A5
Description: Be effective at once
5.23 Read MAC binding status, turn MAC binding on and off
Command
Respond
Parameter
RequestAT+BOND?
+OK=[para]
Para:0,1 ASCII
0Bind off
1Bind on
SetAT+BOND=[para]
+OKsuccess
+ERR=[NUM]error
Description: Be effective at once, save when power-off