User's Manual
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT05 User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd
22
Request:AT+DISCSLEEP?
+OK=[para]
Para: 0、1 ASCII
0:Close
1:Open
Set:AT+DISCSLEEP =[para]
+OK:success
+ERR=[NUM]:error
Description: Be effective at once, save when power off
5.37 Get to sleep mode at once
Command
Respond
Parameter
Request:AT+SLEEP?
STA:sleep
None
Description :Be effective at once, if the broadcast is not turned off, the broadcast gap as the wake-up time will continue
broadcasting
5.38 Request/Set print status
Command
Respond
Parameter
Request:AT+LOGMSG?
+OK=[para]
Para: 0、1 ASCII
0:Close
1:Open
Set:AT+LOGMSG=[para]
+OK:success
+ERR=[NUM]:error
Description: Be effective at once, save when power off
5.39 Read IO0 input
Command
Respond
Parameter
Request:AT+ IO0?
+OK=[para]
Para: 0,1 ASCII
0:low level
1:High level
Description: Be effective at once, save when power off
5.40 Read IO1 input
Command
Respond
Parameter
Request:AT+ IO1?
+OK=[para]
Para: 0,1 ASCII
0:low level
1:High level
Description: Be effective at once
5.41 Set IO2 output
Command
Respond
Parameter
Request:AT+ IO2=[para]
+OK:success
Para: 0,1 ASCII