User's Manual

Chengdu Ebyte Electronic Technology Co., Ltd E104-BT05 User Manual
Copyright ©20122019Chengdu Ebyte Electronic Technology Co.,Ltd
22
RequestAT+DISCSLEEP?
+OK=[para]
Para: 01 ASCII
0Close
1Open
SetAT+DISCSLEEP =[para]
+OKsuccess
+ERR=[NUM]error
Description: Be effective at once, save when power off
5.37 Get to sleep mode at once
Command
Respond
Parameter
RequestAT+SLEEP?
STA:sleep
None
Description :Be effective at once, if the broadcast is not turned off, the broadcast gap as the wake-up time will continue
broadcasting
5.38 Request/Set print status
Command
Respond
Parameter
RequestAT+LOGMSG?
+OK=[para]
Para: 01 ASCII
0Close
1Open
SetAT+LOGMSG=[para]
+OKsuccess
+ERR=[NUM]error
Description: Be effective at once, save when power off
5.39 Read IO0 input
Command
Respond
Parameter
RequestAT+ IO0?
+OK=[para]
Para: 01 ASCII
0low level
1High level
Description: Be effective at once, save when power off
5.40 Read IO1 input
Command
Respond
Parameter
RequestAT+ IO1?
+OK=[para]
Para: 01 ASCII
0low level
1High level
Description: Be effective at once
5.41 Set IO2 output
Command
Respond
Parameter
RequestAT+ IO2=[para]
+OKsuccess
Para: 01 ASCII