User's Manual
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT05 User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd
23
+ERR=[NUM]:error
1:high level
0:low level
Description:
1.Be effective at once, save when power off
2.IO Keep setting level after next power-on
5.42 Set IO3 output
Command
Respond
Parameter
Request:AT+ IO3=[para]
+OK:success
+ERR=[NUM]:error
Para: 0,1 ASCII
1:High level
0:Low level
Description:
1. Be effective at once, save when power off.
2.IO Keep setting level after next power-on
5.43 Read/set PWM0 duty cycle
Command
Respond
Parameter
Request:AT+PWM0?
+OK=[para]
Para: 0~100% ASCII
0 close PWM
Set:AT+PWM0=[para]
+OK:success
+ERR=[NUM]:error
Description: Be effective at once, save when power off.
5.44 Read/Set PWM1 duty cycle
Command
Respond
Parameter
Request:AT+PWM1?
+OK=[para]
Para: 0~100% ASCII
0 close PWM
Set:AT+PWM1=[para]
+OK:success
+ERR=[NUM]:error
Description: Be effective at once, save when power off.
5.45 Read/set PWM2 duty cycle
Command
Respond
Parameter
Request:AT+PWM2?
+OK=[para]
Para: 0~100% ASCII
0 close PWM
Set:AT+PWM2=[para]
+OK:success
+ERR=[NUM]:error
Description: Be effective at once, save when power off.