- 1.Overview
- 2.Technical parameter
- 3. Mechanical characteristics
- 4. Operation mode
- 5.Transmission mode
- 6.Application function and instruction configurati
- 6.1 Function pin
- 6.2 Wireless remote configuration function
- 6.3 Touch link Functional application
- 6.4 Functional parameter description
- 6.5 HEX User instruction set
- 6.6 HEX Parameter description
- 6.6.1 System transmitting mode
- 6.6.2 Receiving data output mode
- 6.6.3 Network node type
- 6.6.4 Network state
- 6.6.5 Network PAN_ID
- 6.6.6 Network short address:
- 6.6.7 MAC address
- 6.6.8 Short address of father nodes
- 6.6.9 MAC address of father nodes
- 6.6.10 Network group number group
- 6.6.11 Network Channel
- 6.6.12 Transmitting Power
- 6.6.13 Buad rate
- 6.6.14 Sleep time
- 6.6.15 Storage time of father nodes
- 6.6.16 Centralized network opening time
- 6.6.17 Period of network reconnection after loss o
- 6.6.18 The maximum number of attempts to reconnect
- 6.6.19 Wireless remote configuration ID
- 6.6.20 User gpio parameter
- 6.6.21 User pwm parameter
- 6.6.22 User adc parameter
- 6.6.23 Configure all network parameters
- 6.6.24 Configure all network parameters
- 6.6.25 Number of end-devices of the parent node
- 6.6.26 Parent node's end-device list
- 6.6.27 Configure the delayed printing time of AUX
- 6.6.29 Configure endpoint information
- 6.6.30 Set Link key of trust center
- 6.6.31 firmware version number
- 7.Quick start
- 8. Secondary development design reference
- 9.FAQ
- Revision history
- About us

Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co.,Ltd.
16
the corresponding mode function introduction;
Output mode
Read/Write
0、1、2、3、
4、5
The data output mode is:
Transparent transmission;
Data + short address;
Data + long address;
Data + RSSI;
Data + short address + RSSI;
Data + long address + RSSI;
Remote
configuration
ID
Read/Write 2 byte
It is used to determine whether the data received by the air in the
air is a remote configuration command. The customer can change
the unlimited configuration ID according to the requirements. The
default is A8 8A;
Local network
group number
Read/Write 0~255
Used to configure the device number of the device in network;
Target network
group number
Read/Write 0
~
255
Group number corresponding to the target when configuring device
multicast;
Wake-up period
(sleep time)
Read/Write 0
~
2010s
It is used to configure the wake-up cycle of the end-device sleep device.
The larger the cycle is, the lower the overall power consumption is, but
the greater the delay of receiving data is;
Network
opening time
Read/Write 10~2540s
It is used to configure the opening and closing of network security.
During the opening period, the device can join the network, and during
the closing period, the device cannot join;
Lost parent node
reconnection
period
Read/Write
1~255
minutes
When the parent node is lost (the coordinator is powered down), the end-
device reconnects the previous network at regular intervals;
Maximum
number of
reconnections
Read/Write
1 to 255
times
After the parent node is lost, the maximum number of
reconnections, if it has not been reconnected successfully, clears
the previous network information, rescans the new network, and
the scanning period is equal to the reconnection period;
IO state Read/Write High/Low
Access/control module level status of the GPIO channel;
PWM Read/Write 1
~
65535ms
Access/control module duty cycle and period of the PWM
channel;
ADC value Read 0
~
3700mv
Read the ADC value of the device, where 0 channel can read the
device power voltage value, and the ADC can detect 3.7V voltage
when the voltage is up to 3.7V;