Users Manual
Table Of Contents
- FCC Statement
- 1.Overview
- 2.Technical parameter
- 3. Mechanical characteristics
- 4. Operation mode
- 5.Transmission mode
- 6.Application function and instruction configurati
- 6.1 Function pin
- 6.2 Wireless remote configuration function
- 6.3 Touch link Functional application
- 6.4 Functional parameter description
- 6.5 HEX User instruction set
- 6.6 HEX Parameter description
- 6.6.1 System transmitting mode
- 6.6.2 Receiving data output mode
- 6.6.3 Network node type
- 6.6.4 Network state
- 6.6.5 Network PAN_ID
- 6.6.6 Network short address:
- 6.6.7 MAC address
- 6.6.8 Short address of father nodes
- 6.6.9 MAC address of father nodes
- 6.6.10 Network group number group
- 6.6.11 Network Channel
- 6.6.12 Transmitting Power
- 6.6.13 Buad rate
- 6.6.14 Sleep time
- 6.6.15 Storage time of father nodes
- 6.6.16 Centralized network opening time
- 6.6.17 Period of network reconnection after loss o
- 6.6.18 The maximum number of attempts to reconnect
- 6.6.19 Wireless remote configuration ID
- 6.6.20 User gpio parameter
- 6.6.21 User pwm parameter
- 6.6.22 User adc parameter
- 6.6.23 Configure all network parameters
- 6.6.24 Configure all network parameters
- 6.6.25 Number of end-devices of the parent node
- 6.6.26 Parent node's end-device list
- 6.6.27 Configure the delayed printing time of AUX
- 6.6.29 Configure endpoint information
- 6.6.30 Set Link key of trust center
- 6.6.31 firmware version number
- 7.Quick start
- 8. Secondary development design reference
- 9.FAQ
- Revision history
- About us

Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co.,Ltd.
20
external MCU serial port
in wireless receiving state
Read UART wake up
keep time
36
Send: FE 01 36 FF
Return: FB 36 Uart_holdtime
Send: FE 01 36 FF
Return: FB 36 64
Read port info.
37
Send: FE 05 37 FF
Return: FB 37 Endpoint_info
Send: FE 05 37 FF
Return: FB 37 01 FE B0
05 04
Read link key of trust
center
38
Send: FE 10 38 FF
Return: FB 10 TrustCentLinkKey
Send: FE 10 38 FF
Return: FB 38
5A 69 67 42 65 65 41 6C
6C 69 61 6E 63 65 30 39
6.5.3 Configuration instruction set
Configure device type
Send
:
FD 01 01 dev_type FF
Return
:
FA 01
Send
:
FD 01 01 03 FF
Return
:
FA 01
Configure PAN_ID
Send
:
FD 02 03 pan_id FF
Return
:
FA 03
Send
:
FD 02 03 FE 5B FF
Return
:
FA 03
Configure the network
group number
Send:FD 01 09 group FF
Return:FA 09
Send:FD 01 09 01 FF
Return:FA 09
Configuring
communication channel
Send:FD 01 0A channel FF
Return:FA 0A
Send:FD 01 0A 0B FF
Return:FA 0A
Configure transmit power
Send:FD 01 0B txpower FF
Return:FA 0B
Send:FD 01 0B 0A FF
Return:FA 0B
Configure serial port baud rate
Send:FD 01 0C baud FF
Return:FA 0C
Send:FD 01 0C 09 FF
Return:FA 0C
Configure sleep time
(end-device valid)
Send
:
FD 01 0D sleep_time FF
Return
:
FA 0D
Send
:
FD 01 0D 54 FF
Return
:
FA 0D
Configure the target
network short address
Send
:
FD 02 23 dec_addr FF
Return
:
FA 23
Send
:
FD 02 23 00 00 FF
Return
:
FA 23
Configure the target
network group number
Send:FD 01 24 netid FF
Return:FA 24
Send:FD 01 24 00 FF
Return:FA 24
Configure target long
address
Send:FD 08 25 dec_mac FF
Return:FA 25
Send:FD 08 25 0A 1C 21
FE FF 57 B4 14 FF
Return:FA 25
Configure system send
mode
Send:FD 01 26 mode FF
Return:FA 26
Send:FD 01 26 02 FF
Return:FA 26
Configure the data output
mode
Send:FD 01 27 mode FF
Return:FA 27
Send:FD 01 27 00 FF
Return:FA 26
Configure to open
centralized network time
Send
:
FD 01 28 time FF
Return
:
FA 28
Send
:
FD 01 28 FF FF
Return
:
FA 28
Configure the period of
rejoin after the end-device
Send
:
FD 01 29 time FF
Return
:
FA 29
Send
:
FD 01 29 05 FF
Return
:
FA 29