Users Manual
Table Of Contents
- FCC Statement
- 1.Overview
- 2.Technical parameter
- 3. Mechanical characteristics
- 4. Operation mode
- 5.Transmission mode
- 6.Application function and instruction configurati
- 6.1 Function pin
- 6.2 Wireless remote configuration function
- 6.3 Touch link Functional application
- 6.4 Functional parameter description
- 6.5 HEX User instruction set
- 6.6 HEX Parameter description
- 6.6.1 System transmitting mode
- 6.6.2 Receiving data output mode
- 6.6.3 Network node type
- 6.6.4 Network state
- 6.6.5 Network PAN_ID
- 6.6.6 Network short address:
- 6.6.7 MAC address
- 6.6.8 Short address of father nodes
- 6.6.9 MAC address of father nodes
- 6.6.10 Network group number group
- 6.6.11 Network Channel
- 6.6.12 Transmitting Power
- 6.6.13 Buad rate
- 6.6.14 Sleep time
- 6.6.15 Storage time of father nodes
- 6.6.16 Centralized network opening time
- 6.6.17 Period of network reconnection after loss o
- 6.6.18 The maximum number of attempts to reconnect
- 6.6.19 Wireless remote configuration ID
- 6.6.20 User gpio parameter
- 6.6.21 User pwm parameter
- 6.6.22 User adc parameter
- 6.6.23 Configure all network parameters
- 6.6.24 Configure all network parameters
- 6.6.25 Number of end-devices of the parent node
- 6.6.26 Parent node's end-device list
- 6.6.27 Configure the delayed printing time of AUX
- 6.6.29 Configure endpoint information
- 6.6.30 Set Link key of trust center
- 6.6.31 firmware version number
- 7.Quick start
- 8. Secondary development design reference
- 9.FAQ
- Revision history
- About us

Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co.,Ltd.
32
(
3
)Modify the node type as sleep-end-device, click the Enter button, the message box prompts "Configure device
type is successful", modify the network parameters, its PAN ID and transmit channel parameters must be the same as the
network to be joined, click "Write network parameters", The message box prompts "Write parameters successfully."
(
4
) Click "Module Restart", the message box prompts "Module restart is successful", click "Enter configuration
mode", the message box prompts "Enter configuration status is successful, read parameters successfully", confirm
whether the read PAN ID and transmit channel parameters are Modified value before.
(
5
) Select the fixed-point networking interface and display the network status as “joined network”. The sleep-
end-device node has joined the network created by the former coordinator.