Users Manual

Chengdu Ebyte Electronic Technology Co., Ltd. E22-900T30S User manual
Copyright ©20122018Chengdu Ebyte Electronic Technology Co.,Ltd.
20
03H
Read/W
rite
REG0
765 UART: Serial port ratebps
000: 1200
001: 2400
010: 4800
011: 9600default
100: 19200
101: 38400
110: 57600
111: 115200
---------------------------------------
43 Serial parity bit
008N1default
018O1
108E1
118N1equal to 00
-----------------------------------
210air data rate
000: 0.3k
001: 1.2k
010: 2.4kdefault
011: 4.8k
100: 9.6k
101: 19.2k
110: 38.4k
111: 62.5k
For the two modules that communicate with
each other, the serial port baud rate can be
different, and the verification method can also
be different.
When transmitting large packets continuously,
users need to consider the data blocking caused
by the same baud rate, and data may even be
lost. It is generally recommended that both
parties have the same baud rate.
---------------------------------------
Both parties must be the same
The higher the rate, the shorter the distance
04H
Read/W
rite
REG1
76 Sub packet setting
00: 240 bytesdefault
01: 128 bytes
10: 64 bytes
11: 32 bytes
--------------------------------------
5 RSSI Ambient noise enable
1: Enable
0: Disabledefault
--------------------------------------
432 Reserve
--------------------------------------
When the data is smaller than the sub packet
length, the serial output of the receiving end is
an uninterrupted continuous output.
When the data is larger than the sub packet
length, the receiving end serial port will output
the sub packet.
--------------------------------------------
When enabled, the C0 C1 C2 C3 command can