User's Manual

Chengdu Ebyte Electronic Technology Co,;Ltd E70-915T30S user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 19
open drain. But in some cases, it may need external
pull-up resistor.
1
TXD
AUX open-collector outputs, RXD
open-collector inputs
1
0
transmission power (approximation)
The external power must ensure that the ability of
current output is more than 80mA and the power
supply ripple is within 100mV.
Low power transmission is not recommended due
to its low power supply efficiency.
For example: The meaning of No.3 "SPED" byte
The binary bit of the byte
7
6
5
4
3
2
1
0
The specific value
(configured by user)
0
0
0
1
1
0
1
0
Meaning
UART parity bit 8N1
UART baud rate is
9600
Air data rate is 2.4k
Corresponding hexadecimal
1
A
8.Parameter Setting
When the module is in Mode 3 (M0=1 M1=1 M2=0) or Mode 5 (M0=1 M1=0 M2=1), the parameter can be set by
instruction or software in PC. Please visit www.cdebyte.com to download the software.