INSTALLATION LOCATION & METHOD CONTINUED...
7) Connect the valve cover.
Water connections
1. All water pipe must comply with national and applicable state and local water pipe codes.
2. The unit should be connected directly to the main water supply. Flush pipe with water to remove any debris or
loose particles
3. It is required that 3/4” NPT water connections be used with the following models, iE11, iE18, iE24, iE27.
4. Please remember to install rubber seal rings at the connections. When all water connections are completed,
check for leaks and take corrective action before proceeding.
5. Connect the cold water supply to the threaded pope labeled “Inlet” and the hot water to the threaded pipe
labeled “o\Outlet”. IMPORTANT: RUBBER WASHER MUST BE USED FOR PROPER SEAL.
Electrical connection
1. All electrical work must comply with national and applicable state and local electrical codes
2. All units must be connected to a properly grounded dedicated branch circuit of proper voltage rating.
3. Before beginning any work on the electric installation, be sure that main breaker panel switch is OFF to avoid
any danger of electric shock, all mounting and plumbing must be completed before proceeding with electrical
hook-up.
4. iE11 can be connected to a single circuit, use a supply cable protected by a double pole breaker. Connect the
cold water supply to the threaded pope labeled :inlet” and the hot water to the threaded pipe labeled “outlet”.
IMPORTANT: RUBBER WASHER MUST BE USED FOR PROPER SEAL.
5. iiE18 require two independent circuits. Use two supply cables protected by two separate double pole breakers.
6. iE24, iE27 require three independent circuits. Use three supply cables protected by three separate double pole
breakers.
7. While feeding the cable to terminal blocks, please make sure the metal wire ends and the terminal blocks touch
completely. Then tighten the screws to make sure there is full contact and the current can go through.