Installation Guide
12
DO NOT RETURN TO STORE:
Call Eccotemp directly toll free at
866.356.1992 or via email at
info@eccotemp.com if you encounter a
problem!
TROUBLE SHOOTING
Unit will not start – there are no audible clicks at startup:
a. The first thing to check is to ensure that the incoming water
on the "right" side of the unit. If the incoming and outgoing are
reversed, the unit will not work. The incoming is on the far
right and the outgoing is in the middle.
b. The "On/Off" switch should be with the “—“ sign pushed
down.
c. Check to make sure you have fresh batteries and they are
installed in the correct position.
d. Number one reason that the unit does not ignite is that
there is not enough water pressure. You need to make sure
that you have a minimum of 20 PSI of sustained water
pressure.
ADJUSTMENT: Looking up at the bottom of the unit, you will
see 2 oval holes in the case. The hole that is furthest on the
right looks up at the water regulator where you will see two
Philip head screws. Take the screw that is furthest on the
right in about a ¼ or ½ turn. This will enable the unit to
operate on a lower water pressure by restricting flow.
There is a simple test that we can help you perform if you are
unaware if you have enough water pressure. Please call our
tech support line at 866.356.1992 for further instructions.
9
8. Turn the spray nozzle to the “on” and adjust to the
desired water pattern on the shower head.
9. There will be a series of audible clicks and the burner
will ignite. (Should the burner not ignite after 5
seconds, shut off and go to the “Trouble Shooting”
section.)
10. After use, open the drain valve (ribbed cylindrical
stem next to the water input valve) to ensure draining
of water.
WARNING: If the outside temperature is around or below
freezing (32 degrees F, 0 degrees C), ensure that the
drain valve is opened and water drained from the unit
after each use to avoid internal damage to the water
regulator. You will also need to unhook the outgoing
water line to ensure that any water in the heat exchanger
is drained. Failure to properly drain your unit will cause
water damage which may or may not be reparable.
Please check the warranty information found on our
website at
www.eccotemp.com/freeze.htm for more
information on freezing issues.