User's Manual

ANSI Electric Meter v3.1 User’s Guide 33
Status Name Description Event ID Descriptor
Time Changed
(new time)
If procedure 10 (absolute change) is used
for the time change, this event time is the
new time that was set.
If procedure 2064 (gradual change) is
used for the time change, this event time
is the resulting new time after completion
of the gradual change.
4
Meter Accessed
for Write
Date and time an outside source wrote
data into a meter table or via a meter
procedure into a table.
8
Procedure
Invoked
Date and time an outside source invoked
a specific meter procedure. Enabling this
event allows access to the procedure
folders. Choose those procedures that
are to trigger this event.
9 Procedure number
Table Written To Date and time an outside source wrote to
a specific meter table. Enabling this
event allows access to the table folders.
Choose those tables that, when written
to, are to trigger this event.
10 Table number
Reset List
Pointers
List pointers for load profile, self read or
event log were reset. This changes the
number of unread records to zero.
14 2 = self read
3, 7 = load profile
8 = event log
255 = all of the above
Update List
Pointers
List pointers for load profile, self read, or
event log were updated. This changes
the number of unread records.
15 2 = self read
3, 7 = load profile
8 = event log
255 = all of the above
Event Log
Erased
The event log was erased. 18
Event Log
Pointers
Changed
Event log pointer position was changed. 19 New value for pointer
Demand Reset
Occurred
A demand reset has occurred. 20
Self-Read
Occurred
A Self-Read occurred. 21
Daylight Saving
Time On
The meter switched into Daylight Saving
Time.
22
Daylight Saving
Time Off
The meter switched out of Daylight
Saving Time.
23