User's Manual

44 Meter Operation
Table Name Description
2048 Calibration Data Contains the meter calibration data for power
measurement.
2049 KYZ Setup Contains the KYZ pulse rate and width.
2050 Clock Calibration Contains the calibration parameters for the Real Time
Clock.
2051 Utility Information 2 The utility serial number, program date and time, program
number and program ID, and metering point identifier.
2052 System Information Contains node, PLC setup information, as well as meter
configuration and LonTalk information.
2053 Disconnect and Control Relay
Settings
Contains settings for the load disconnect and control relay.
2055 Display Data Formatting Sets data formatting and name-plate message for the
meter display.
2057 Power Quality Contains the power quality settings and recorded data.
2061 MEP Device Configuration Contains the programmable configuration settings for each
commissioned MEP device.
2070 Error Codes Configuration Configuration of error codes shown on meter display.
2075 Transaction Requests Contains records of transaction requests.
2078 Maximum Power Level Control Contains the configuration information and status of the
maximum power level control.
2079 One-time-read Data A snapshot of the present register data taken at the
programmed One-time-read time intervals. The most
recent data set and up to 11 sets of previous One-time-
read data sets are included.
2080 MEP One-time-read Data A snapshot of the present MEP data taken at the
programmed MEP One-time-read time intervals. The most
recent and up to 11 sets of previous MEP One-time-read
data are included.
2081 Group Configuration Contains the group IDs assigned to the meter for group
broadcast messages.
2082 MEP Device Configuration
Parameters
Contains additional M-Bus and MEP device configuration
parameters used for time synchronization and group
broadcasting.
2086 Configuration ID Log Contains a log of subsets of the meter’s configuration
parameters.
2087 Previous Demand Contains the demand values calculated at the end of the
last demand sub-interval for each of the configured
demand registers. Its values are set to 0 before demand is
activated and configured.