User's Manual

62 Meter Operation
The measured electrical values are:
Active power (kW), summation: forward, reverse
Active energy (kWh), summation: forward, reverse, forward + reverse,
forward – reverse. Forward – reverse is limited to zero at the bottom of the
range, negative values are not accumulated.
Reactive power (kvar), summation: import, export
Reactive energy (kvarh), summation: import, export
RMS voltage, per phase
RMS current, per phase
Power factor, per phase
Frequency
Sine of phase angle, per phase
Apparent power (VA), summation
Maximum active power: forward, reverse
Maximum reactive power per quadrant
Maximum, continuous, and cumulative demand values
Previous demand values
Minimum and maximum per-phase voltages
Energy Register Capacity
The energy registers contain the present metering values of summation and
instantaneous items, previous season data, and self-read data. The capacity of the
energy registers is 999,999,999 Wh/varh (9 digits).
The Energy Register Capacity setting also affects the capacity of the number of
power-off minutes, the number of power outages recorded, and the number of alarms
occurrences in the error counter. When the capacity is reached by any of these
values (including Wh/varh), the value rolls back over to zero.
Note: The meter display shows 8 digits. When you set the energy register capacity to
9 digits, the highest number may not be shown on the display (depending on
display configuration).
Error Occurrence Recording
Certain errors can be recorded and are accumulated in a meter register. The count is
incremented by one for every error occurrence. The errors are:
RAM Failure
Non-Volatile Memory Failure
Clock Error
Measurement Error
Save-All Aborted
See “Diagnostic Event Descriptions” on page 1 for details of these errors.