Instruction Manual
54  Managing a Street Lighting Network 
•  Delete devices 
Analyzing a Power Line Repeating Network 
When running on a power line repeating network, the Segment Controller 
transmits network messages to the repeating devices with which it can directly 
communicate, and those repeating devices in turn relay the messages to 
repeating devices located further down the power line, and so on until the 
message reaches the target device.  Figure 2 on page 5 illustrates a repeating 
chain that could be used to relay a network management command from the 
Segment Controller to a target device. A luminaire enabled for repeating would 
use power line repeating. A CRD 3000 Street Light Bridge module could use 
power line repeating or forward the message using an RF channel to another 
CRD 3000 Street Light Bridge module. 
You can use the Power Line Repeating Analysis Web page to view the repeating 
chain a device is using to communicate with the Segment Controller. In addition, 
you can use this Web page to analyze and debug the power line repeating 
network.  
To open and use the Power Line Repeating Analysis Web page, perform the 
following steps: 
1.  Right-click the Segment Controller icon, select Setup, and select Power 
Line Repeating Analysis from the shortcut menu.  Alternatively, you 
can click the Tools icon and select Power Line Repeating Analysis. 
2.  The Power Line Repeating Analysis Web page opens.  
The rows in this Web page represent established repeating paths between 
the listed devices. The target device in a repeating chain is listed 