Use and Care Manual
99944200640 MAINTENANCE
X7712092800 19
© 02/2017 ECHO Inc.
ENGLISH
2. Carefully pump grease into fit-
ting (A). DO NOT force grease.
Too much pressure will force
grease past seals and cause
damage. Apply 1 - 2 pumps of
grease every 15 - 25 hours of
operation.
3. Wipe excess grease from
around grease fitting.
Drive Shaft Assembly
Level 1.
Hedge Trimmer blades are very sharp. Touching them may lead
to severe personal injury. Avoid touching blades whenever pos-
sible, and always wear gloves to protect hands.
1. Remove gear housing locating
screw (A) and loosen clamping
screw (B). Remove the gear
housing assembly from the
drive shaft housing.
Parts Required: Lithium based grease.
A
A
A
A
B
B
D
A