Operator's Manual

Table Of Contents
SRM-225 OPERATION
X7732273804 27
© 11/19 ECHO Incorporated
1. Stop Switch
Move stop switch (A) away from
the STOP position.
2. Purge Bulb
Pump purge bulb (C) until fuel is
visible and flows freely in the
clear fuel tank return line. Pump
bulb an additional 4 or 5 times.
Note: Energy is stored in the
starter spring each time
the handle/rope is pulled.
Generally two to six pulls,
using light pulling force,
will store enough energy
to engage the starter and
spin the engine. Do not pull the rope out to end stop.
3. Recoil Starter
Lay the unit on a flat area and
keep movable attachment parts
clear of all obstacles. Firmly grip
throttle handle with left hand.
Gently pull recoil starter handle/
rope (D) until engine fires.
Note: If engine does not start after 2-3 engine engagements, use
Cold Start Procedure.
A
C
D