B-FOCuS O-4F2P Optical Network Termination (ONT) Installation and Configuration Manual 417006-2305-0H3-A04
B-FOCuS O-4F2P Installation and Configuration Manual August 2010 © Copyright by ECI Telecom, 2010. All rights reserved worldwide. This is a legal agreement between you, the end user, and ECI Telecom Ltd. (“ECI Telecom”). BY OPENING THE DOCUMENTATION AND/OR DISK PACKAGE, YOU ARE AGREEING TO BE BOUND BY THE TERMS OF THIS AGREEMENT.
Contents About This Manual ........................................................................ vii Purpose .............................................................................................................. vii Intended Audience ............................................................................................. vii Overview ............................................................................................................ vii Document Conventions ..........................
Contents ii B-FOCuS O-4F2P ECI Telecom Ltd.
List of Figures Figure 1: B-FOCuS O-4F2P ........................................................................................... 1-1 Figure 2: B-FOCuS O-4F2P product bottom label ......................................................... 2-1 Figure 3: ONT Top View ................................................................................................ 3-1 Figure 4: ONT Connector View ......................................................................................
List of Tables Table 1: Physical specification ....................................................................................... 1-3 Table 2: Electrical specification ...................................................................................... 1-3 Table 3: Environmental specification ............................................................................. 1-3 Table 4: Compliance ......................................................................................................
About This Manual Purpose This guide describes how to install ECI’s Optical Network Termination (ONT) unit, B-FOCuS O-4F2P, at the customer premises.
About This Manual B-FOCuS O-4F2P connecting service cables, activating the ONT, and verifying the installation. | Chapter 4: Layer 3 Configuration Describes the procedures required to configure the system for layer 3 configuration. It details the GUI menu screens and lists the required parameters to be configured and options available | Chapter 5: Troubleshooting Explains ONT LED behavior and provides basic troubleshooting guidelines.
B-FOCuS O-4F2P About This Manual LASER WARNING: Text set off in this manner indicates how to avoid personal injury. All personnel involved in equipment installation, operation, and maintenance must be aware that laser radiation is invisible. Therefore, although protective devices generally prevent direct exposure to the beam, personnel must strictly observe the applicable safety precautions and, in particular, must avoid staring into optical connectors, either directly or using optical instruments.
About This Manual B-FOCuS O-4F2P Technical Assistance The configuration, installation, and operation of ECI Telecom products in a network are highly specialized processes. Due to the different nature of each installation, some planning aspects may not be covered in this manual.
1 Product Description Introduction The B-FOCuS model O-4F2P Optical Network Terminal is an ITU-T G.984 compliant device that receives voice, data, and video traffic in the form of optical signal from the service provider’s passive optical network (PON) and transmitted it to the desired format at residential or business premises. Upstream traffic is likewise transmitted to the PON network via the fiber optic cable. A single optical fiber carries both upstream and downstream traffic.
Product Description B-FOCuS O-4F2P Services Equipped with ITU-T G.984 compliant 2.5Gbps Downlink and 1.25Gbps Uplink GPON interfaces, ONT O-4F2P supports the full Triple Play of services including voice, video (IPTV/VOD), and high speed internet access.
B-FOCuS O-4F2P Product Description Specifications The ONT’s physical, electrical, optical, and environmental specifications and compliance information are listed in the following tables. Table 1: Physical specification Dimensions 130mm (height) by 172mm (width) by 33mm (depth) Weight 0.
Product Description B-FOCuS O-4F2P Table 5: Optical specification Minimum Nominal Maximum Wavelength 1260 nm 1310 nm 1360 nm Transmit power 0.5 dBm Notes Transmitter +5 dBm Digital receiver Wavelength 1480 nm Sensitivity -27 dBm Overload 1-4 1490 nm 1500 nm Minimum received power for BER<10-10 -8 dBm ECI Telecom Ltd.
2 Safety CAUTION: Product installation should be performed only by trained service personnel. Read and follow all warning notices and instructions marked on the product or included in its packaging, and observe all safety instructions listed in this guide while handling any ONT. Figure 2: B-FOCuS O-4F2P product bottom label ECI Telecom Ltd.
Safety B-FOCuS O-4F2P Electrical Safety | Always use caution when handling live electrical connections. | Do not install electrical equipment in wet or damp conditions. | Ensure that the power source for the system is adequately rated to assure safe operation and provides current overload protection. | Do not allow anything to rest on the power cable, and do not place this product where people will stand or walk on the power cable.
3 Installation Get to Know the ONT Look through the diagram below for getting an overview of several parts of the ONT. Laser Lock Door Figure 3: ONT Top View ECI Telecom Ltd.
Installation B-FOCuS O-4F2P Power Connector Figure 4: ONT Connector View Two power connector types are available: The barrel (power) connector (as shown in Figure 4) is for use with the standard DC power adaptor. An 8-pin molex connector which can be connected either to a standard DC connector (supplied with the unit) or to a Battery Backup Unit (BBU a.k.a. UPS) The following defines the pin numbering of the 8-Pin Power BBU molex connector.
B-FOCuS O-4F2P Installation Site Preparation Environmental Requirements The ONT ambient temperature should not exceed 45° C and a relative humidity ranging from 5% to 95%. Installation Location The ONT should be located within 2 meters of the closest electrical point and within reach of the fiber termination point.
Installation B-FOCuS O-4F2P Wall or Table-Top Mounting Wall Installation - Recommended The ONT must be installed with the cables leaving the ONT in the downward direction. The placement of the ONT should leave at least 8 cm of free space below the ONT for cables to exit with an adequate bend radius. Two centimeters should be left free on all sides of the unit to allow ventilation. 11 cm Figure 6: ONT Mounting On the wall, draw a horizontal line 3 cm from the top of where the ONT is to be placed.
B-FOCuS O-4F2P Installation Connecting to Network 1. Remove the screw and pull the Laser Lock Door in up to down direction, Push the corner of Laser Lock Door to 15 degree and pull at the same time. Figure 7: Remove the Laser Lock Door NOTE: If necessary, hold the unit steady while opening and closing the Laser Lock Door. 2. Remove the Laser Lock Door 3. Remove the dust covers from the SC/APC optical connectors. Clean the connector if necessary. ECI Telecom Ltd.
Installation B-FOCuS O-4F2P 4. Plug in the fiber connector to connect the B-FOCuS O-4F2P to the network. Figure 8: Plug in the fiber connector 5. Attach the Laser Lock Door to the B-FOCuS O-4F2P. Figure 9: Attach the Laser Lock Door 3-6 ECI Telecom Ltd.
B-FOCuS O-4F2P Installation Connecting Power Mains Power 1. Plug the circle two pin (or 8-pin Molex ) 12V DC power connector of power converter to ONT O-4F2P power port 2. Plug the input of power converter into a live AC outlet 3. Verify that the power (POWER) LED on the ONT O-4F2P is lit green indicating that local power is on and voltage is good. Using a BBU When a BBU is used, connect the Molex connector from the BBU into the Power connector instead of the regular AC/DC adaptor.
Installation B-FOCuS O-4F2P Connecting Ethernet Lines 1. Locate the premises’ Ethernet LAN cable. 2. If the cable is not terminated, follow local practices to attach an RJ-45 connector. Table shows Ethernet RJ-45 connector wiring information. 3. Plug the Ethernet cable into the B-FOCuS O-4F2P RJ-45 Ethernet port. 4. Repeat step 2-3 as needed to connect additional Ethernet cables.
B-FOCuS O-4F2P Installation Figure 10: B-FOCuS O-4F2P has not yet been provisioned Figure 11: B-FOCuS O-4F2P has already been provisioned 1. Verify that the POWER LED lights green indicating that local power level is good. 2. Verify that the OPTICAL LED lights green indicating that the B-FOCuS O4F2P is operating normally.
Installation B-FOCuS O-4F2P Verifying Services Follow local practices to connect to each active service port in the B-FOCuS O4F2P to confirm service activation. 1. Connect to each active phone jack to verify telephone numbers and services. Verify that the POTS LED lights green when a line is off hook. 2. If Ethernet service is included in this installation, confirm that data is being received and transmitted normally. The LAN LED flashes during data transmission.
4 Layer 3 Configuration This section describes the procedures required to configure the B-FOCuS O-4F2P Optical Network Terminal (ONT) system for layer 3 configuration. It details the GUI menu screens and lists the required parameters to be configured and options available. Logging In To log into the B-FOCuS’s GUI menu screens: 1. Connect the PC LAN connection to one of the Layer 3 UNI connections (Ethernet port 1 or 2). 2.
Layer 3 Configuration B-FOCuS O-4F2P Default user name: root Default password: admin The default user name and password can be changed, as described in the Maintenance section below. Note: If the user name /password have been changed and are not known, you can reset the system and revert to the default user name /password values by pressing the Reset button for more than 5 seconds. Be aware that this will also reset all other configured values to the factory defaults. 4-2 ECI Telecom Ltd.
B-FOCuS O-4F2P Layer 3 Configuration Status The Status screens allow you to view the status details of the B-FOCuS ONT device and of the WAN connection. All values in these status screens are read only. Device Info The Status > Device Info screen is the initial screen shown when accessing the GUI. It presents information about the B-FOCuS ONT device.
Layer 3 Configuration B-FOCuS O-4F2P WAN Status The Status > WAN Status screen shows status details of the WAN connection. Note: These parameters are defined by the user in the Network > WAN screen, as detailed below. The following details are shown: 4-4 • Internet Connection Type (PPPoE, DHCP, or Static IP) • Connection status • IP Address • Subnet Mask • Default gateway • DNS Server 1 • DNS Server 2 ECI Telecom Ltd.
B-FOCuS O-4F2P Layer 3 Configuration Network Configuration Network configuration consists of defining the LAN and the WAN connection parameters. LAN Configuration The LAN configuration parameters can be configured.
Layer 3 Configuration B-FOCuS O-4F2P • Option60 Class ID1 - Starting IP Address • Option60 Class ID1 - Max Number of Option60 Users • Option60 Class ID2 • Option60 Class ID2 - Starting IP Address • Option60 Class ID2 - Max Number of Option60 Users WAN Configuration The WAN configuration parameters can be configured. There are three Internet connection types available – the ways to get the WAN IP address: PPPoE, DHCP, or Static IP.
B-FOCuS O-4F2P Layer 3 Configuration • Default gateway is supplied by the provider • DNS Server 1 is supplied by the provider • DNS Server 2 is supplied by the provider (optional) • User Name and Password (for PPPoE dialup, unique) is supplied by the provider • Connection Mode: select Keep Alive or Manual • Redial Period (in seconds) can be entered (valid values: 5-25) DHCP WAN Configuration: DHCP internal client should be selected and configured when the client serviced by a High Speed Intern
Layer 3 Configuration B-FOCuS O-4F2P Static IP WAN Configuration: Static IP should be selected and configured when the client serviced by a High Speed Internet Provider uses a DHCP server with unique Static IP Address distribution.
B-FOCuS O-4F2P Layer 3 Configuration Advanced Operations The Advanced screens allow you to configure a few advanced features – SNTP, DDNS, port forwarding, and the firewall. SNTP Configuration The SNTP configuration parameters can be configured. Select to Enable or Disable the SNTP State.
Layer 3 Configuration B-FOCuS O-4F2P DDNS Service The DDNS configuration parameters can be configured. Select the DDNS Service from the drop-down list (None, DynDNS.org, or TZO.com). The screen will refresh with the appropriate parameters that can be configured. If DynDNS.org is selected, the following details can be entered: • User Name • Password • Host Name If TZO.com is selected, the following details can be entered: 4-10 • Email Address • Tzo Password • Domain Name ECI Telecom Ltd.
B-FOCuS O-4F2P Layer 3 Configuration Port Forwarding Port forwarding rules can be configured. For each port forwarding operation required, enter the following parameters: • Application name • Start and end ports (valid values: 0-65535) • Protocol – select TCP, UDP or Both from the drop-down list • To IP Address • Start and end ports (valid values: 0-65535) • Check to enable ECI Telecom Ltd.
Layer 3 Configuration B-FOCuS O-4F2P Firewall The firewall configuration parameters can be configured (Web access can be enabled/disabled) and you can make an internal host work as the DMZ host. The following parameters can be configured: 4-12 • Web Access from LAN – select Enable or Disable • Web Access from WAN – select Enable or Disable • DMZ – select Enable or Disable • DMZ Host – enter the IP address • UPnP Enable – select Enable or Disable ECI Telecom Ltd.
B-FOCuS O-4F2P Layer 3 Configuration Maintenance Operations The Maintenance screens allow you to configure a few maintenance features: • Changing the password • Restore to factory default • Reboot the device • Upgrade the firmware Change Password The default user name/password is root/admin. The password should be changed if security is required. In the Maintain > Password screen, enter, and re-enter to confirm, the new password. ECI Telecom Ltd.
Layer 3 Configuration B-FOCuS O-4F2P Reset Factory Default You can reset the system configuration, including all configured values (as well as the defined user name and password) to their default factory values by clicking Reset in the Maintenance > Factory Default screen. Note: In addition to using this screen, the system configuration can be reset to the factory default values by pressing the Reset button on the back of the B-FOCuS for more than 5 seconds.
B-FOCuS O-4F2P Layer 3 Configuration Upgrade Firmware If a firmware upgrade is needed, you can select the firmware file to be uploaded in the Maintenance > Upgrade screen. The new firmware file (software image), supplied by the system vendor, should be saved on the local PC. To upgrade the firmware, click Browse to select the firmware file stored on the local PC, and click Upgrade. The firmware will automatically be uploaded to the device and installed. ECI Telecom Ltd.
Layer 3 Configuration 4-16 B-FOCuS O-4F2P ECI Telecom Ltd.
5 Troubleshooting B-FOCuS O-4F2P Status LEDs The B-FOCuS O-4F2P status LEDs located on the enclosure (Figure 12) assist with installation and maintenance procedures. These LEDs are described in detail in Table 9. Figure 12: B-FOCuS O-4F2P Status LEDs location ECI Telecom Ltd.
Troubleshooting B-FOCuS O-4F2P Table 9: B-FOCuS O-4F2P Status LEDs description LED Name POWER OPTICAL Color Indicates Green/Solid B-FOCuS O-4F2P operating from AC power. Green/Flash System Booting. Red/Solid Optical interface abnormal (LOS/LOF). Green/Solid B-FOCuS O-4F2P working normally. Green/Flash B-FOCuS O-4F2P in ranging and synchronization process. Bridge At least one of the Ethernet links is up. PPPoE/DHCP signup completed successfully. Internet is now connected.
B-FOCuS O-4F2P Troubleshooting Troubleshooting Procedures Table 10: Troubleshoot procedures Problem Possible Solutions Make sure the power cable connector is properly seated in the B-FOCuS O-4F2P power input. Verify that the power adapter is plugged into a live AC outlet. Check the power cable for shorts or breaks. The POWER LED is off Check the status of the POWER Button. If it is lit in red, push and release the button to turn on the power.
Troubleshooting 5-4 B-FOCuS O-4F2P ECI Telecom Ltd.