Specifications

Troubleshooting B-FOCuS O-4F2P
5-2 ECI Telecom Ltd. Proprietary
Table 9: B-FOCuS O-4F2P Status LEDs description
LED Name Color Indicates
POWER
Green/Solid
B-FOCuS O-4F2P operating from AC power.
Green/Flash
System Booting.
OPTICAL
Red/Solid
Optical interface abnormal (LOS/LOF).
Green/Solid
B-FOCuS O-4F2P working normally.
Green/Flash
B-FOCuS O-4F2P in ranging and synchronization process.
LAN
Green/Solid
Bridge Gateway
At least one of the Ethernet
links is up.
PPPoE/DHCP signup
completed successfully.
Internet is now connected.
Green/Flash
At least one of the Ethernet
links is up and there is
activity of receiving and
transmitting data.
L2 path is completed and
now is proceeding with
PPPoE/DHCP signup.
OFF
No Ethernet link is up or the
B-FOCuS O-4F2P is not
ready for running Ethernet
service.
No service is configured or
provisioned.
UPDATE
Green/Flash
The device in upgrading process, but the data traffic is not
affected.
Red/Solid
Upgrade failure.
OFF
B-FOCuS O-4F2P working normally.
ALARM
Green/Solid
No alarm with local access enabled
Red/Flash
Software out of order.
Red/Solid
Hardware out of order.
OFF
No alarm.
POTS
Green/Solid
At least one POTS interfaces is in off-hook condition.
Green/Flash
At least one POTS interfaces is in off-hook condition for at
least one hour.
OFF
All POTS interfaces are in the on-hook condition or the B-
FOCuS O-4F2P is not ready for running POTS service.