R410A SPLIT SERIES FIXED SPEED QUICK COUPLING Models ECO902SQN ECO1202SQN ECO1802SQN R ead This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. Review the chart of Troubleshooting Tips before calling your service engineer.
BS PLUG WIRING (For models up to 12000 Btu) Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the
CONTENTS DISPOSAL Disposal........................................................................................................................................2 SAFETY PRECAUTIONS Warning ........................................................................................................................................3 Caution .........................................................................................................................................
DISPOSAL When using this air conditioner in the European countries, the follow information must be followed: DISPOSAL: Do not dispose this product as unsorted waste. It is prohibited to dispose of this appliance in domestic household waste. For disposal, : A) Contact your local council for disposal. B) The manufacture will take back the old appliance for disposal when you replace with a new product. C) Old products contain valuable resources, which should be recycled as scrap metal.
SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation may cause harm or damage. The seriousness is classified by the following indications. WARNING Failure to follow these instructions exactly, can cause property damage, death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to property. Meanings of symbols used in this manual are as shown below. Never do this.
SAFETY PRECAUTIONS CAUTION ! ! When the air filter is to be removed, do not touch the metal parts of the unit. Do not clean the air conditioner with water. It may cause an injury. Water may enter the unit and degrade the insulation. It may cause an electric shock. An oxygen shortage may occur. When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not put a pet or house plant where it will be exposed to direct air flow. Do not use for special purposes.
OPERATING INSTRUCTIONS Parts names Indoor unit Indoor unit 2 4 1. 2. 3. 4. 5. 6. 7. 8. 3 1 5 7 6 AUTO COOL DRY HEAT 9 SET TEMP ERAT URE (C Outdoor unit ) FAN HIGH MED LOW TEMP MOD E ON/O SWING FF FAN SLEE P DIRECAIR TION 8 Front panel Air inlet Air filter Air outlet Horizontal air flow grille Vertical air flow louver Display panel Remote controller SPEE D TIME R ON RESET LOCK TIME LED DISPL AY R OFF TURB O 9. Connecting pipe, drain hose 10. Air inlet (side and rear) 11.
OPERATING INSTRUCTIONS NOTE: This manual does not include Remote Controller Operations, which is provided separately. Operating temperature Mode Temperature Cooling operation >17 C Room temperature 18 C• Outdoor temperature Heating operation Drying operation >10 C <30 C 43 C -15 C• 43 C:(For the models with low temperature cooling system) 11 C• 4 3 C -7 C• 24 C O O 21 C ~52 C: (For O O 21 C ~52 C: (For special tropical special tropical models ) models ) CAUTION: 1.
OPERATING INSTRUCTIONS Airflow direction control Adjust the air flow direction as appropriate to maximise comfort and even room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. To set the vertical air flow(Up--Down) direction Perform this function whilst the unit is in operation using the remote controller.The horizontal louver moves at a 6O angle each time the AIR DIRECTION button is pressed.
OPERATING INSTRUCTIONS How the air conditioner works SLEEP operation 1 Set Temperature 1 1 hour 1 hour Cooling SLEEP operation When you push SLEEP button on remote controller during cooling or heating, or AUTO operation, the air conditioner will automatically increase (cooling) or decrease (heating) 1 per hour.
CARE AND MAINTENANCE Care and maintenance Cleaning the Grille, Case and Remote Controller Household Drain Cleaner Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. No NOTE: Supply power must be disconnectd before cleaning the indoor unit. CAUTIONS Thinner A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit.
CARE AND MAINTENANCE 4. Remove the Air Freshening Filter(Optional filter included: Plasma Dust Collector/Silver Ion filter / Bio filter /Vitamin C filter/3M air purifier filter) from its support frame.(The removing and installation method may differ slightly, see the pictures marked 1 and 2 on the left. Clean the air freshening filter at least once a month, and replace it every 4-5 months. Clean it with vacuum cleaner, then air dry it in cool area.
OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. A) When heating has just starting. B) Defrosting. C) Low temperature heating.
OPERATION TIPS 7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 8. Heating mode (For cooling and heating models only) The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation.
TROUBLESHOOTING TIPS Troubleshooting Tips Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators flash rapidly (5 times every second) and this flash can't be fixed by disconnecting the power, and then connect it in again. Trouble Fuse blows frequently or circuit breaker trips frequently. Other objects or water penetrate the air conditioner.
ONE (1)YEAR LIMITED WARRANTY Save This Warranty Information EcoAir guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded. This unit must be operated under conditions as recommended, at voltages indicated on the unit. Any attempts made to service or modify the unit by unqualified technician, will render this WARRANTY VOID.