R410A SPLIT SERIES FIXED SPEED QUICK COUPLING Models ECO902SQN ECO1202SQN ECO1802SQN Before using your air conditioner, please read this manual carefully and keep it for future reference.
BS PLUG WIRING (For models up to 12000 Btu) Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the
CONTENTS SAFETY PRECAUTIONS Warning .....................................................................................................................................2 Caution ......................................................................................................................................2 INSTALLATION INSTRUCTIONS Selecting the location.........................................................................................................3 Accessories ........ ....................
SAFETY PRECAUTIONS Read these SAFETY PRECAUTIONS carefully to ensure correct installation. Precautions are classified as WARNING and CAUTION. Ensure all precautions are observed as they are important to ensure your safety. Failure to observe precautions may cause grave consequences. WARNING Failure to follow any WARNING is likely to result in grave consequences such as death or serious injury. CAUTION Failure to follow any CAUTION may result in grave consequences in some cases.
INSTALLATION INSTRUCTIONS Selecting the location More than 15cm Indoor unit Do not expose the indoor unit to heat or steam. More than 12cm More than 12cm Select a place where there are no obstacles in front or around the unit. Make sure that condensation drainage water from Indoor unit can be conveniently routed away. More than 2m Do not install near a doorway. Fig.1 Ensure that the space on the left and right of the unit is more than 12cm.
INSTALLATION INSTRUCTIONS Accessories Number Q ty Name of Accessories 1 Installation Plate 1 2 Clip Anchor 8 3 Self-tapping Screw A - ST3.9X25 8 4 1 5 Seal(see page 8 for details) Drain Plug(see page 8 for details) 6 Remote controller 1 7 Self-tapping Screw B - ST2.9X10 2 8 Remote controller holder 1 1 Note: The above parts are provided,certain other parts needed during installation are not provided.
INSTALLATION INSTRUCTIONS Indoor unit installation Correct orientation of Installation Plate 1. Fit the Installation Plate 1. Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate. 2. If the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter holes in the wall. Insert Clip anchor for appropriate mounting screws. 3. Fit the installation plate on the wall with eight (8) type “A” screws. Fig.
INSTALLATION INSTRUCTIONS 3. Drainage Installation 1. Run the drain hose sloping downward to ensure condensation water is being drained externally, any rise in the drain hose will prevent condensation water to flow externally on gravity as illustrated below (Fig. 7). Condensation Water Do not form a rise Do not put the hose end into water Fig.7 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, avoiding any slack on the drain hose. 4.
INSTALLATION INSTRUCTIONS CAUTION Do not allow the pipin g to let out from the back of the indoor unit. Be careful not to let the drain hose slack or bend sharpley. The connective pipes must be heat insulated. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause condensation tray to overflow inside the unit. Never intercross nor intertwist the power wire with any other wiring.
REFRIGERANT PIPE CONNECTION Drain plug installation Fit the seal into the drain elbow, then insert the drain plug into the base pan hole of outdoor unit, rotate 90 to securely assemble them. Connect the drain plug to an extension drain hose to drain water from the outdoor unit during heating mode. Seal Drain Plug Base pan hole of outdoor unit Seal Drain pipe Fig.12 Refrigerant pipe connection CAUTION: For your safety, always wear safety eye wear and work gloves when connecting the pipes.
ELECTRICAL WORK To disconnect the couplings: Step 1: Shut down the A/C unit and unplug the electrical power cord from the wall outlet. Step 2: Wait five minutes for the line pressure between the indoor unit and outdoor condensing unit to equalize. Step 3: Pull the male coupling handle up and toward the male coupling to the full back position. Step 4: Retract the Release Sleeve on the female coupling to release the male coupling half from the female half.
ELECTRICAL WORK Model <12000Btu/h >12000Btu/h Input Rated Amp (Switch/Fuse) Power supply 220-240V~ 50Hz or 220-230V~ 60Hz 13A 20A NOTE: The supply voltage can not be less than the rate voltage of the air conditioner. CAUTION CAUTION CAUTION After the confirmation of the above conditions, prepare the wiring as follows: 1) Be sure to use a dedicated power circuit specifically for the air conditioner.
MEMO Date of installation: Purchased from (Dealer Name): Date of purchase: Model number: Serial number:
ONE (1)YEAR LIMITED WARRANTY Save This Warranty Information EcoAir guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded. This unit must be operated under conditions as recommended, at voltages indicated on the unit. Any attempts made to service or modify the unit by unqualified technician, will render this WARRANTY VOID.