Unit installation

7
INSTALLATION INSTRUCTIONS
Do not allow the piping to let out from the back of the indoor unit.
Be careful not to let the drain hose slack or bend sharpley.
The connective pipes must be heat insulated.
Be sure that the drain hose is located at the lowest side of the bundle. Locating
at the upper side can cause condensation tray to overflow inside the unit.
Never intercross nor intertwist the power wire with any other wiring.
Run the drain hose sloping downward to drain out the condensed water smoothly.
CAUTION
Install the outdoor unit on a solid and level base to prevent excessuve noise level and vibration.
Determine the air outlet direction where the discharged air is not blocked.
In the case that the installation place is exposed to strong wind such as a seaside,
make sure the fan operates properly by putting the unit lengthwise along the wall
or using a dust or shield plates.
In coastal or windy area, install the unit to prevent the exposure to strong winds.
If mounting on wall brackets, the installation brackets must be suitable for the weight and size
out the outdoor unit. The installation wall should be solid
brick, concrete or the same intensity construction,
or actions to reinforce, damping supporting should
be taken. The connection between brackets,
wall and the air conditioner must be
firm, stable and reliable.
Be sure there is no obstacle blocking
radiating air.
Outdoor unit installation
Outdoor installation precaution
Strong
wind
Fig.10
Settlement of outdoor unit
Anchor the outdoor unit with a bolt and nut
10 or 8 tightly and horizontally on a
concrete or solid mount.
A
B
Air inlet
Air outlet
Air inlet
Fig.11
Outdoor unit dimension
mm(W
xHxD)
A(mm)
458
460
B(mm)
250
276
530
290
560
335
549
276
Mounting dimensions
700x535x235
685x430x260
780x540x250
760x590x285
845x695x335