Instruction manual

4.3. Controller’s technical data .
L.p. Description j.m. Value
1. Power AC ~V/Hz 230/50±10%
2. Power consumption (controller) VA <5
OUTPUT LOAD
3. Central heating pump W 100
4. Hot water pump W 100
5. Buffer pump W 100
6. Heater W 400
7. Blower W 150
8. Gear-motor 1 W 200
9. Gear-motor 2 W 150
10. Mixing valve actuator
W
50
11. Boiler temp. range
ºC
60-85
12. Hot water temp. range
ºC
35-70
13. Measurement accuracy
ºC
±2
14. Ambient temperature
ºC
0-60
15. Moisture content
%
5-95 without condensation
16.
Alarm temp. - range
ºC
80-95
18
L.p. Description j.m. Value
7. Approximate heating space m
2
to 250
8. Max working pressure bar 2,5
9. Max water temp. °C 85
10. Min. return water temp. °C 60
11. Flue diameter mm 10
12. Required chimney draught mbar from 0,1 to 0,2
13. Fumes temp:
nominal
minimal
°C 160
130
14. Fumes ow:
nominal
minimal
kg/s
kg/s
0,02
0,01
15. Weight kg 320
16. Water capacity l 60
17. Hopper capacity l 255
18. Loading opening dimensions width/length mm 260/432
19. Cooling coil water temperature °C 10
20. Min water pressure in cooling coil bar 2
21. Voltage/Frequency AC V/Hz 230/50
22. Auxiliary power W 250
23. Recommended capacity of accumulation tank litres 1000-2000