Owners manual

10
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
JET/TANK PUMP ASSEMBLY
Tank
1. Remove tank from its carton.
2. Using a tire pressure gauge, check the air in the tank.
It may need to be adjusted once you know the on/o settings on the pump’s pressure switch
(see number 3 below).
Pump
1. Remove the pump from its carton.
2. Retain the pump’s owners manual.
3. Remove the cover from the pump’s pressure switch, and read the on/o settings from the underside of the
pressure switch cover. Typically readings are:
a. Pump (motor) on pressure: 30 PSI (pounds per square inch);
b. Pump (motor) o pressure: 50 PSI.
4. Once you know the turn on/o pressures, alter the air pressure in the empty pre-charge tank to 2 (two) PSI below
the “on” pressure, i.e. to 28 PSI.
5. It is critical the pressure in the tank be 2 PSI below the “tank turn” on pressure
Mounting Kit
1. Remove the kit’s contents and sort them into groups.
Jet Tank Assembly
1. Mount the jet on to the tank securing the jet with the 4 bolts, washers, and nuts provided in the kit.
2. Ensure the input end of the pump is on the same end of the tank input end.
3. Snug the nuts on the bolts while you install other pieces of the kit.
4. Use Teon tape or other plumbing sealant to ensure all connections are sealed.