User's Manual

12
CONFIGURING THE IGATE
CONNECT THERMOSTAT
The  rst step after installing the iGate
Connect
thermostat is to con gure the settings for the
equipment being connected.
An access code is required to enter the
Installation Settings menu. The access code is
4795.
Thermostat Con g
Aux Heat Option
Con gures the thermostat for electric auxiliary
heat or no auxiliary heat (none).
Equipment
Capacity Con guration
Min Heating Capacity Con gures the
minimum unit heating capacity. When the
space requires a heating capacity below this
setting the unit will cycle o . Range will
depend on unit model.
Max Heating Capacity Con gures the
maximum unit heating capacity. When the
space requires a heating capacity above this
setting the unit will call for auxiliary heat (if
applicable). Range will depend on unit model.
Min Heating Air ow Con gures the unit
air ow while operating at minimum capacity
in the heating mode. The installer may wish
to select a higher cfm than the nominal cfm
for this setting to ensure proper air movement
To con gure the iGate
Connect thermostat:
From the Home screen,
press MENU.
Select Settings
Installation.
Select Thermostat Con g.
To con gure equipment
on the iGate
Connect
thermostat:
From the Home screen,
press MENU.
Select Settings
Installation.
Select Equipment.