User's Manual

21
Compressor Speed – displays the current compres-
sor speed in revolutions per second.
Comp Current – displays the current compressor
amperage.
Inverter Current – displays the amperage draw of
the inverter.
Comp Input Power – displays the power consump-
tion of the compressor in watts.
Comp DC Voltage – displays the current DC bus
voltage from the inverter.
Comp Heat Sink Temp – displays the temperature
of the inverter heat sink.
– Blower Diagnostics
ECM Target Air ow displays the blower target
cfm.
ECM Blower Speed – displays the blower rpm.
ECM Blower Power – displays the power consump-
tion of the blower in watts.
ECM Blower Static – not used.
Leaving Air – displays the temperature of the air
leaving the unit.
Entering Air – displays the temperature of the air
entering the unit.
– Loop Diagnostics
Loop Pump Speed – displays the speed of the loop
pump as a percentage.
Loop Pump Watts – displays the power consump-
tion of the loop pump in watts.
Loop Flow – displays the source  ow rate in gpm.
Entering Water displays the temperature of the
water entering the source heat exchanger.
Leaving Water displays the temperature of the
water leaving the source heat exchanger.
Water pressure – displays the pressure of the water
as it leaves the source heat exchanger.
Hot Water Pump Diagnostics (If Applicable)
DHW Pump Speed – displays the speed of the DHW
pump as a percentage.