Specifications

14
Step E: Install RO Faucet
INSTALL BATTERY
When the coin battery is first applied at initial start up,
the LED indicator light will flash in red, amber, green
sequence. All timers and counters are reset to zero. In
order to reset the time and gallon count feature, push the
button on the PWA and hold until the LED flashes and
release.The battery needs to be replaced at the time of
filter replacement. Use only lithium batteries (CR 2032 or
equivalent). Improper placement of battery could damage
electronics. Use care when inserting the battery to align it
correctly on the PWA with the proper polarity.
Battery
PWA Board
Reset Button
SELECT LOCATION OF REVERSE OSMOSIS
FAUCET MOUNTING HOLE
You will need to select the location of the Reverse
Osmosis Faucet. You have three options to choose from:
Use the existing sink top hole for the spray hose or
soap dispenser (Must be 1-1/4” in diameter)
Drill a new hole in the sink
Drill a new hole in the countertop next to the sink
1. Determine where you are going to install your Reverse
Osmosis Faucet.
2. Check to ensure the Reverse Osmosis faucet will
mount flat against the mounting surface.
3. Visually review the routing of the tubes from the
Reverse Osmosis filter assembly to the faucet. Check
to ensure there is adequate tube routing space
between the faucet and filter assembly.
4. If drilling is needed, drill a 1-1/4" diameter hole in the
mounting surface.
IMPORTANT: Drilling holes into countertops and
sinks should only be performed by an installer who
is qualified for drilling such materials. Drilling of
surfaces made of stone or solid surface materials
such as granite, marble, Corian™ or other plastic
resin products or sinks made of porcelain or stain-
less steel may cause permanent, irreparable dam-
age to the sink or countertop surface.
FIG. 15