Troubleshooting guide

OPERATING THE FIRE (manual control models) - continued
To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clockwise
to the high (large flame) position. The main burner should light after a few seconds.
To decrease the setting to LOW, turn the control knob clockwise to the low setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and
return to the pilot position and release.
To turn the fire OFF, keep the knob pressed in, return to the off position and release.
A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled suffi-
ciently to allow the magnetic valve unit to reset itself.
OPERATING THE FIRE
(remote control models)
The pilot is visible through the left hand side of the
front ceramic strip. Turn the main burner control
(shown on left hand side of control valve) knob fully
anti-clockwise.
Turn ignition knob (shown on right hand side of control
valve) slightly left towards the ignition position until
reaching the stop, press down and hold for 5 seconds
(only pilot gas is flowing).
Continue pressing down the knob while turning further to the left to
activate the piezo spark, continue to hold the knob down for a further
10 seconds after the pilot has been lit. If the pilot does not light repeat
the previous steps.
Upon lighting and after the further 10 seconds, release the knob and
turn further to the left to the ON position. The main burner will light
and be controlled in accordance with the main burner control knob set-
ting. Adjust the main burner control knob to the desired setting.
If the pilot is extinguished during use of the fire, you MUST wait ten
minutes before repeating the ignition procedure.
To turn the main burner OFF whilst keeping the pilot flame lit, turn the
ignition control knob to the pilot position then only the pilot will
remain lit.
To shut the fire off completely, press the ignition control knob down
and continue turning to the right from the pilot position to the OFF position.
A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled suffi-
ciently to allow the magnetic valve unit to reset itself.
The remote control unit allows operation of the main burner setting between maximum and pilot
only setting. It does not permanently turn the pilot on or off.
The remote control handset incorporates an inbuilt safety feature to prevent the main burner
being activated or turned up accidentally. It is necessary to press button 1 and 2 (see illustration)
simultaneously to turn the fire up.
To turn the fire down press button 3 only.
SPARK FAILURE
The gap between the spark electrode and the pilot should be 3.5 - 4.5mm to produce a good
spark.
There should be no need to adjust this. If under any circumstances the electric spark fails, the
pilot may be lit manually by proceeding with the ignition sequence as previously described, and
after turning the control knob through the spark position, the knob should be held in and the
pilot lit with a taper.