Report No.: 18270BC10173705 MSDS REPORT Client Name : EcoFlow Inc. Address Factory Building A202, Founder Technology Industrial Park, North side of Songbai Highway, Longteng Community, : Shiyan Sub-district, Baoan District Shenzhen City, Guangdong, China Product Name : Portable Power Station Date : Aug.
Report No.: 18270BC10173705 Page 2 of 8 MATERIAL SAFETY DATA SHEET 1. Chemical Product and Company Identification Sample name: Portable Power Station Sample model: EFD500-EB Rating: Nominal Voltage: 48V Rated Capacity: 3600Wh Weight: 37.9kg Manufacturer: EcoFlow Inc. Address: Factory Building A202, Founder Technology Industrial Park, North side of Songbai Highway, Longteng Community, Shiyan Sub-district, Baoan District Shenzhen City, Guangdong, China EcoFlow Inc.
Report No.: 18270BC10173705 Page 3 of 8 2. Composition/Information on Ingredients Chemical Name Percent of Content CAS No. Lithium iron phosphate (LiFePO4) 25%~30% 15365-14-7 Graphite (C) 8%~12% 7782-42-5 LiPF6 15%~22% 21324-40-3 Aluminum(AL) 5%~8% 7429-90-5 Copper(Cu) 10%~15% 7440-50-8 High molecular polymer 3%~5% - Nickel (Ni) 0.5%~1% 7440-02-0 Iron (Fe) 22%~30% 7439-89-6 3. Hazards Summarizing Danger sort: N/A Routes of entry: 1.
Report No.: 18270BC10173705 Page 4 of 8 4. First Aid Measures Skin contact: Not anticipated. If the battery is leaking and the contained material contacts the skin, flush with copious amounts of clear water for at least 15 minutes. Eye contact: Not anticipated. If the battery is leaking and the contained material contacts eyes, flush with copious amounts of clear water for at least 15 minutes. Get medical attention at once. Inhalation: Not anticipated. If the battery is leaking, remove to fresh air.
Report No.: 18270BC10173705 2. 3. 4. 5. 6. 7. Page 5 of 8 cause the battery to flame. When charging the battery, use dedicated chargers and follow the specified conditions. Never disassemble or modify a battery. Do not immerse, throw, and wet a battery in water. Should a battery unintentionally be crushed, thus releasing its contents, rubber gloves must be used to handle all battery components. Avoid the inhalation of any vapors that may be emitted. Short circuit causes heating.
Report No.: 18270BC10173705 Page 6 of 8 Body Protection: Not necessary under conditions of normal use. Use rubber apron and protective working in case of handling a leaking of ruptured battery. Protective Gloves: Not necessary under conditions of normal use. Use chemical resistant rubber gloves if handling a leaking or ruptured battery. Others: Use good chemical hygiene practice. Wash hands thoroughly after cleaning-up a battery spill caused by leaking battery.
Report No.: 18270BC10173705 Page 7 of 8 Carcinogenicity: No information is available. Mutagenicity: No information is available. Reproductive toxicity: No information is available. 12. Ecological Information 1. When properly used and disposed, the battery does not present environmental hazard. 2. The battery does not contain mercury, cadmium, or lead. 3. Do not let internal components enter marine environment. Avoid releasing to water ways, wastewater or ground water. 13. Disposal Considerations 1.
Report No.: 18270BC10173705 Page 8 of 8 (a) UN number 3480&3481 (b) UN Proper shipping name LITHIUM ION BATTERIES (including lithium ion polymer batteries) or; LITHIUM ION BATTERIES CONTAINED IN EQUIPMENT or LITHIUM ION BATTERIES PACKED WITH EQUIPMENT (including lithium ion polymer batteries) (c) Packing Instruction (if applicable) 965 IA, 966 I, 967 I (d) Marine pollutant (Yes/No) No (e) Transport in bulk (according to Annex II of MARPOL 73/78 and the IBC Code) No information available.