Product Specs

Table Of Contents
6 Recommended operating conditions
Page
20
6
Recommended operating conditions
The operating conditions are the physical parameters that the chip can operate within.
Table 8: Recommended operating conditions
Symbol
Parameter
Notes
Min.
Nom.
Max.
Units
VDD
Supply voltage, independent of DCDC enable
1.7
3.0
3.6
V
t
R_VDD
Supply rise time (0 V to 1.7 V)
60
ms
TA
Operating temperature
-40
25
85
°C
Important: The on-chip power-on reset circuitry may not function properly for rise times longer than
the specified maximum.