Product Specs

Table Of Contents
40 WDT Watchdog timer
Page
415
Bit number
31 30
29
28
27
26
25
24
23 22 21 20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Id
A A
A
A
A
A
A
A
A A A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Reset 0x00000000
0 0
0
0
0
0
0
0
0 0 0 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Id
RW Field
Value Id
Value
Description
A W RR Reload request register
Reload 0x6E524635 Value to request a reload of the watchdog timer
40.4.14 RR[6]
Address offset: 0x618
Reload request 6
Bit number
31 30
29
28
27
26
25
24
23 22 21 20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Id
A A
A
A
A
A
A
A
A A A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Reset 0x00000000
0 0
0
0
0
0
0
0
0 0 0 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Id
RW Field
Value Id
Value
Description
A W RR Reload request register
Reload 0x6E524635 Value to request a reload of the watchdog timer
40.4.15 RR[7]
Address offset: 0x61C
Reload request 7
Bit number
31 30
29
28
27
26
25
24
23 22 21 20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Id
A A
A
A
A
A
A
A
A A A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Reset 0x00000000
0 0
0
0
0
0
0
0
0 0 0 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Id
RW Field
Value Id
Value
Description
A W RR Reload request register
Reload 0x6E524635 Value to request a reload of the watchdog timer
40.5 Electrical specification
40.5.1 Watchdog Timer Electrical Specification
Symbol
Description
Min.
Typ.
Max.
Units
I
WDT
Run current for watchdog timer
0.3
2
µA
t
WDT
Time out interval
458 µs
36 h