EcoFlow Wave 2 User Manual V1.
Disclaimer Please read the product document and ensure that you understand it fully before using the product. After reading this document, keep it for future reference. Improper use of this product may cause serious injury to yourself or others, or cause product damage and property loss. Once you use this product, it is deemed that you understand, approve and accept all the terms and content in this document.
Contents Specifications Safety Instructions 1 2 Use 2 Grounding Guide 3 EcoFlow App What's in the Box Product Details 4 4 5 Overview 5 Light Effect 6 LCD 6 Control Buttons 7 Getting Started 8 How to Install 8 How to Power-on 10 How to Drain 13 How to Clean 13 Troubleshooting and Display FAQ Care and Maintenance 14 15 16
Specifications Cooling/Heating Specifications Model EFKT210 Cooling Capacity/Heating Capacity 1500 W/1800 W Temperature Setting Range 16°C-30°C (60°F-86°F) Refrigerant R290 (130g) Air Flow Volume 290 m³/h Cooling/Heating Rated Input (AC) 560 W Cooling/Heating Rated Input (DC) 505 W Maximum Cooling/Heating Power 700 W Input Specifications AC Input 100-240 V~50/60 Hz, 820 W max Car Charging Input 12V/24 V 8 A, 200 W max Solar Input 11-60 V 13 A, 400 W max External Battery Pack Input 700
Safety Instructions Use 1. Do not use this product near a heat source (such as fire or heater), and avoid direct exposure to sunlight. Doing so may cause flammable liquids to leak or explode. 2. If the product catches fire by accident, we recommend that you use fire extinguishers in the following order: water or water mist, sand, fire blanket, dry powder, and carbon dioxide. 3. Keep the product away from any liquid. Do not get the product wet, and try to avoid working in a wet location. 4.
hearing aids, defibrillators and so on. If you are using these medical devices, please consult the manufacturers about the restrictions on the use of relevant devices to ensure that a safe distance is maintained between this product and the implanted medical devices (such as pacemakers, cochlear implants, hearing aids, defibrillators and so on) during operation. 21.
What's in the Box Wave 2 Exhaust duct adapter cover A Exhaust duct adapter cover B 127mm(5 in) Exhaust duct D Exhaust duct adapter cover C Winder 150mm(5.9 in) (12.2-55.1 in) 310-1400mm (12.2-55.1 in) 310-1400mm Window baffle 216mm(8.5 in) 376mm(14.8 in) User Manual & Warranty Card Exhaust duct E Drain pipe The types of AC charging cable(pluggable/embedded) vary due to local regulatory requirements, please refer to the actual product.
Product Details Overview 1. LCD 6. AC charging cable 2. Control buttons 7. Add-on battery socket (XT150) 3. Front air outlet fan blade 8. Solar/car charging socket (XT60) 4. Ambient light 9. Charging port cover 5. Front air inlet & air filter 10. Winder socket 11. Rear air outlet 13. Drainage outlet 12.
Introduction to light effect Breathing blue Cooling status Breathing orange Heating status Breathing white Fan status Red light constant on Error alarm Flashing white Firmware update LCD 1. Wi-Fi/Bluetooth 7. Timing (Supported in app settings only) 2. Water level indication 8. Remaining charge/discharge time 3. External drainage indication 9. Add-on battery charge indication 4. Cooling/Heating/Fan function 10. Temperature setting/Error code 5. Max/Sleep/Eco mode 11. Error alarm 6.
Control Buttons Function selection Power button Mode Temperature- Temperature+ Fan speed control selection Power button Press Power-on/Screen-off. If there is no operation within 5 minutes, the LCD and ambient light will be off automatically. Press any button to wake them up. Press and hold Press and hold it for 3 seconds for power-off. Function selection Press Switch cooling /heating /fan functions.
Getting Started How to Install Indoor Applications When the air conditioner is used in an enclosed space, you can discharge the exhaust gas by installing an air conditioner exhaust duct for more efficient cooling or heating. The exhaust duct shall not be excessively stretched or bent when it is connected to avoid wind drag that affects the working efficiency of air conditioner.
DIY Instructions on Window Baffle A window baffle is delivered with Wave 2. The baffle can be used after being cut based on the dimensions of the window frame. For the cutting, it is recommended to reserve certain error space to avoid failure of sealing out of too large gap due to expansion caused by heat and contraction caused by cold. 216mm 376mm E Exhaust duct D Exhaust duct E D Do not use the exhaust duct in rainy and snowy days to avoid damaging the product due to wetness.
Outdoor Applications When the interior space is small or when noise cancellation is required, Wave 2 can be placed outdoors and deliver cooling/heating through the exhaust duct.
How to Power-on This product supports multiple charging methods. Open the charging port cover before using it, then power on. Please close the cover to prevent dust during charging, and wind the AC charging cable around the winder. For shutdown, please press and hold the power button before removing the charging cable. Do not directly turn off the power supply for forced shutdown to avoid damaging the battery cell. AC Outlet Wave 2 supports the AC voltage from 100-120 V to 220-240 V.
Battery pack The EcoFlow Wave 2 add-on battery or the portable power station from DELTA family can be used to supply power to Wave 2. The required products and accessories can be purchased in the official distribution channels of EcoFlow. 1. Wave 2 add-on battery 2.
Car Charging Cable Car charging port Only the fan function is supported due to the low power and the voltage instability of car or solar charging. If the cooling/heating function is required, please use it together with the add-on battery/portable power station. How to Drain Wave 2 has no-drain function. When the cooling function is used, the condensate of the air conditioner can be evaporated through flash distillation and external drainage is not required.
Manual drainage: A small amount of residual water will be left at the bottom of the water tank after automatic drainage. Please turn the drainage outlet connector counterclockwise to remove it, and tilt the unit back slightly until the condensate is completely drained to prevent breeding of bacteria. How to Clean The air inlet may be blocked by large amount of dusts and impurities in the air during outdoor application.
Troubleshooting Error Code Error Type Solution 1 Battery pack voltage is too high 1. Turn off all the power supplies; 2. Supply power with battery pack. 2 Battery pack voltage is too low 1. Connect to the household outlet (mains electricity) to charge the battery pack; 4 Bus voltage is too high 1. Please confirm that the range of AC input voltage is 100 V-240 V. If it cannot be confirmed or the voltage is normal, please try the following methods; 2.
FAQ Issue Type Cause Analysis ① It is not powered on or it is not started; ② There are foreign matters Abnormal fan at the air inlet or there are dirt deposits on the fan blades; ③ The fan is not running. Abnormal cooling Abnormal heating Troubleshooting ① Check the power supply or wiring, power on correctly to start it; ② Clean the air inlet filter, and regularly wipe away the dirt on the fan blades; ③ Refer to the solution in [The fan is not running].