SDS
SAFETY DATA SHEET 
ACIDIC TOILET BOWL CLEANER 
923536  2 / 9   
Dispose of contents/ container to an approved waste disposal plant. 
Other hazards 
: 
Do not mix with bleach or other chlorinated products – will cause 
chlorine gas. 
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS 
Pure substance/mixture 
: 
Mixture 
Chemical name 
CAS-No. 
Concentration (%) 
alcohols, c12-16, ethoxylated >5EO 
68551-12-2 
5 - 10 
hydrochloric acid 
7647-01-0 
5 - 10 
SECTION 4. FIRST AID MEASURES 
In case of eye contact 
: 
Rinse immediately with plenty of water, also under the eyelids, for at 
least 15 minutes. Remove contact lenses, if present and easy to do. 
Continue rinsing. Get medical attention immediately. 
In case of skin contact 
: 
Wash off immediately with plenty of water for at least 15 minutes. 
Wash clothing before reuse. Thoroughly clean shoes before reuse. 
Get medical attention immediately. 
If swallowed 
: 
Rinse mouth with water. Do NOT induce vomiting. Never give 
anything by mouth to an unconscious person. Get medical attention 
immediately. 
If inhaled 
: 
Remove to fresh air. Treat symptomatically. Get medical attention if 
symptoms occur. 
Protection of first-aiders 
: 
If potential for exposure exists refer to Section 8 for specific personal 
protective equipment. 
Notes to physician 
: 
Treat symptomatically. 
Most important symptoms 
and effects, both acute and 
delayed 
: 
See Section 11 for more detailed information on health effects and 
symptoms. 
SECTION 5. FIRE-FIGHTING MEASURES 
Suitable extinguishing media 
: 
Use extinguishing measures that are appropriate to local 
circumstances and the surrounding environment. 
Unsuitable extinguishing 
media 
: 
High volume water jet 
Specific hazards during fire 
fighting 
: 
Fire Hazard 
Keep away from heat and sources of ignition. 
Flash back possible over considerable distance. 
Hazardous combustion 
products 
: 
Decomposition products may include the following materials: 
Carbon oxides 
Special protective equipment 
for fire-fighters 
: 
Use personal protective equipment. 
Specific extinguishing 
: 
Fire residues and contaminated fire extinguishing water must be 