3.
INST
ALLA
TION
3.1 General Guidance
1. Do not install near heating and cooling sources.
2. Do not aim detector at windows due to risk of drafts.
3. Do not install outdoors.
4. Do not install where direct sunlight can strike the
unit.
5. Do not install near high-voltage electrical lines.
6. Do not install behind any obstructions.
7. Do not mount on unstable surfaces.
Figure 2. General
Guidelines
3.4 Activating and Pairing the
Detector
To
pair the detector to the control panel, you must set the panel to pairing mode.
1. First set the control panel to pairing mode
.
2. To activate, pull the activation strip that protrudes from the back of the detector or insert the batteries.
3. If required, manually enter in the serial number of the sensor to the control panel.
4.
Verify from the control panel that the sensor has been paired.
Note: Pairing should be performed before
installation.
Note: Serial number is the 6 digits located in the battery compartment
underneath the QR code.
3.2
Installation
Procedur
e
3.5 Rebooting the
Detector
To
reboot the detector, complete the following steps:
1. Remove the battery cover
.
2. Remove the batteries for 3 seconds and reinstall them
.
3. Close the battery cover
.
1.
Separate detector from bracket. Figure 3.
2.
Remove the bracket.
3.
Mount bracket to wall using the center
screw holes (B) or corner screw holes (A1 &
A2). Figure 4.
4.
Install new batteries OR if batteries are
installed, remove the activation strip.
5.
Remount the detector by sliding it down
onto the bracket until a click is heard.
Figure 5.
6.
The unit is ready for walk test.
3.6
Unpair
the
Detector
from Panel
1. Follow control panel instructions to remove the sensor from the network.
3.7
W
alk
T
esting
3.3
Replacing
the
Batteries
While the occupancy sensor is in the 15 minute walk test mode
,
walk across the far end of coverage
pattern in both directions. The LED should light for 2-3
seconds
each time your motion is detected.
1. Press upward to separate the detector
from
the bracket.
2. Replace the ba
tteries.
3. Put back the detector on the bracket.
Note: It is recommended to wait
approximately 1 minute after battery
removal before inserting the new
battery.
CAUTION! Risk of explosion if
battery is replace by an incorrect
type. Dispose of used battery
according to the manufacturer’s
instructions.
Important!
Instruct the user to walk test at
least once a week to verify proper function of
the detector
.
Note:
After battery insertion or closing the
cover (which results in closing the tamper
switch)the LED
flashes for 1 to 2 minutes and
the detector goes into walk-test mode for
15 minutes. In walk test mode
the LED
lights
for every motion detected. After 15 minutes
the detector automatically enters normal
mode
i n which the LED
will not blink after
detection.
Figure 7 Coverage Pattern Walk-Test