Installation Instructions

© 2020 Ecolink Intelligent Technology Inc.
PN DWLZWAVE2.5-ECO R1
COMMAND CLASS and VALUE
ASSOCIATION GROUP
CONFIGURABLE?
Door/Window Open
Notification Report of Access Control
(0x06), Door/Window is open (0x16)
1
Yes via Notification Set of notification Type
(0x06) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on
Sensor Binary Report of 0xFF Sensor
Type: 0xFF
1
Yes via Configuration
Command Class Parameter Number: 2 Size: 1
A Configuration Value: 0xFF (On) / 0x00
(Off)
Basic set of 0xFF (On)
2
No
Door/Window Close
Notification Report of Access Control
(0x06), Door/Window is closed (0x17)
1
Yes via Notification Set of notification Type
(0x06) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on
Sensor Binary Report of 0x00 Sensor
Type: 0xFF
1
Yes via Configuration Command Class
Parameter Number: 2
Size: 1
A Configuration Value: 0xFF (On) / 0x00 (Off)
Basic Set of 0x00 (Off)
By factory default this feature is disabled and
must be enabled via Configuration Command
Class.
2
Yes via Configuration Command Class
Parameter Number: 1
Size: 1
A Configuration Value: 0xFF (On) / 0x00 (Off)
Parameter Number: 2
Sensor Case Removed
Notification Report of Home Security (0x07),
Tampering product cover
removed (0x03)
1
Yes via Notification Set of notification Type
(0x07) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on
Wake-Up Notification
1
Yes via Wake-Up Notification Command
Class
Notification Report of Power
Management (0x08), Replace battery
now (0x0B)
1
Yes via Notification Set of notification Type
(0x08) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on