Installation Instructions

© 2020 Ecolink Intelligent Technology Inc. PN DWWZWAVE2.5-ECO R1
Basic Set of 0x00 (Off)
By factory default this feature is
disabled and must be enabled via
Configuration Command Class.
2
Class Parameter Number: 1
Size: 1
A Configuration Value: 0xFF (On) / 0x00
(Off) Parameter Number: 2
Sensor Case Removed
Notification Report of Home Security
(0x07), Tampering product cover
removed (0x03)
1
Type (0x07) and status of 0x00: This type
of notification turned off
Sensor Case Fastened
Wake-Up Notification
1
Battery Level Dipped Below
2.6v
Notification Report of Power
Management (0x08), Replace
battery now (0x0B)
1
Type (0x08) and status of 0x00: This type
of notification turned off
What is Z-Wave?
The Z-Wave protocol is an interoperable, wireless, RF-based communications technology designed specifically for control, monitoring and status reading applications in
residential and light commercial environments. Mature, proven and broadly deployed (with over 35 million products sold worldwide), Z-Wave is by far the world market
leader in wireless control, bringing affordable, reliable and easy-to-use 'smart' products to many millions of people in every aspect of daily life. Certified Z-Wave devices
regardless of manufacturer can work together to form a Z-Wave mesh network. Always on Z-Wave devices can act as repeaters in the mesh increasing range and
redundancy.
For a more complete look at Z-Wave technology for non-technologists, and to learn more about Z-Wave's role as a key enabling technology for the Internet of Things and
connected objects, please visit www.z-wave.com.
Z-Wave Device Class and Command Class Information
This Z-
Wave sensor is a Z-Wave generic Device Class of GENERIC_TYPE_SENSOR_NOTIFICATION, and a specific device class of
SPECIFIC_TYPE_NOTIFICATION_SENSOR, and the supported command classes are COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_POWERLEVEL, COMMAND_CLASS_BATTERY, COMMAND_CLASS_NOTIFICATION_V4,
COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_WAKE_UP, COMMAND_CLASS_SENSOR_BINARY,
COMMAND_CLASS_CONFIGURATION, COMMAND_CLASS_BASIC.
Manufacturer Specific
Manufacturer ID: 0x014A