User's Manual

© 2017 Ecolink Intelligent Technology Inc. PN FLF-ZWAVE5 R1
LED Status
The Flood Freeze is equipped with a single LED. The state of the LED will change based on the state of the device.
Device not included = Light breathing (slow blink)
Flood Detected = Single LED blink
Freeze Detected = Single LED blink
Case Opened = LED will remain on while case open
Factory Default
The Flood Freeze sensor factory defaults on network exclusion.
Testing
To test the RF transmission from the mounted position you can generate a tamper by removing the cover. This will send a signal to the control panel. To test
flood/water detection, place the probe in a cup of water. Placing the sensor in a freezer to test freezing may not work if the signal cannot penetrate the
appliance. You may place a bag of ice over the sensor to test freeze detection. (may take upwards of 30 minutes to detect)
Replacing the Battery
When the battery is low a low battery notification will be sent to the life line nodes. To replace the battery:
1. Remove the top cover to reveal the battery. This will send a tamper signal to the lifeline nodes.
2. Replace with a Panasonic CR123A battery ensuring the + side of the battery faces as indicated on the device.
3. Re-attach the cover, you should hear a click when the cover engages properly.
Installation
The package contains the following:
1- Flood Sensor with Probe
1- Sensor Mounting Bracket
2- Screws for Sensor Mounting Bracket
1- Adhesive tape for Sensor Mounting Bracket
2- Screws for probe
1- Adhesive tape for mounting Probe.