User's Manual

Datum // date
10.07.2014
Teile-Nr. // part no.
300011
Dokument-Nr. Revision //
document no. revision
300011AL11E 07
Head Module Settings
User Manual
Seite/gesamt // page/total
14 / 25
Dokument erstellt // document created
SAS387 10.07.2014
Dokument geprüft // document checked
FIH091 10.07.2014
User Manual: Head Module Settings
● Ablageort: C:\Users\de0216\Documents\Quellcode\EcomService\user_manual_head_module_settings\300011AL11E07_user_manual_head_module_settings.docx
template no.: 0730QV06A03 template created: HAO006 20.01.2011 template checked: BEA373 20.01.2011 location: ISO drive
CLSI Editing
Enable or disable removing the start and stop
characters and inserting a space after the first, fifth,
and tenth character of a 14-character Codabar
barcode.
NOTIS Editing
Enable or disable removing the start and stop
characters from a Codabar barcode.
Symbologies->MSI
Enable MSI
Enable or disable decoding MSI barcodes.
Length Options
one discrete length = Decodes only those MSI
barcodes that have the specified length.
two discrete lengths = Decodes only those MSI
barcodes that have one of the two specified
lengths.
lengths within a range = Decodes only those
MSI barcodes that have a length which lies in the
specified range.
any length = Decodes MSI barcodes of any length.
Check Digits
Choose how many check digits exists at the end of
the barcode.
Transmit Check Digit
Enable or disable whether the check digit of a
MSI barcode should be transmitted.
Check Digit Algorithm
If you have selected two check digits (see “Check
Digits”) you must select an algorithm to verify the
data of a MSI barcode.
Symbologies->GS1 DataBar
GS1 DataBar 14
Enable or disable decoding GS1 DataBar 14
barcodes.
GS1 DataBar Limited
Enable or disable decoding GS1 DataBar Limited
barcodes.
GS1 DataBar Expanded
Enable or disable decoding GS1 DataBar
Expanded barcodes.
Convert GS1 DataBar to UPC/EAN
Enable or disable conversion of a GS1 DataBar 14
or GS1 DataBar Limited barcode into UPC/EAN.
If the scanned barcode have a single zero as the
first digit, the leading ‘010’ of the barcode is
removed and the barcode is converted into EAN-13.
If the scanned barcode begins with two or more
zeros but not six zeros, the leading ‘0100’ is
removed and the barcode is converted into UPC-A.
In this case the setting UPC-A Preamble which
transmits the system character and country code
has an effect on the scanned barcode.
Symbology Options
Symbology identifier
Enable or disable outputting a code ID character of
a barcode. A code ID character indicates the code
type of a barcode.
Disable = Disables outputting of a code ID
character.
Aim Code ID Character = Enable outputting of the