Specifications

Table 1.1
Size 45 55 65 75
D box E box
m3/h 8100 9000 11500 13500
KW
44,7 52,6 65,4 74,4
43,4 51,0 63,6 71,6
kW 14,8 18,5 21,8 27,4
A
35,7 41,6 52,4 63,3
-
3,4 3,7 3,7 3,2
- 3,03 2,85 3,00 2,72
- 2,94 2,76 2,92 2,62
KW 44,3 51,7 64,6 73,6
43,0 50,1 62,9 70,9
kW 14,8 18,5 21,8
27,4
-
2,99 2,80 2,97 2,69
- 2,91 2,71 2,88 2,59
KW
43,3 51,8 65,8 76,9
kW
42,0 50,2 64,0 74,2
kW 13,50 16,76 19,84
24,07
- 3,11 2,99 3,23 3,08
- 3,21
3,09 3,32 3,20
50% 50% 50% 50%
28,2 33,5 34,3 39,4
7,3 8,9 13,1 16,5
3,86 3,77 2,63 2,40
kW 30.7 / 55.8 30.7 / 55.8 55.8 / 111.6 55.8 / 111.6
kW 33 / 60 33 / 60 60 / 120 60 / 120
% 93 93 92 92
m3/h 3.2 / 5.7 3.2 / 5.7 5.7 / 11.5 5.7 / 11.5
ZP83KCE + ZP83KCE
ZP103KCE + ZP103KCE
ZP154KCE + ZP103KCE ZP154KCE + ZP154KCE
1 x TXV 1 x TXV 2 x TXV 2 x TXV
1 x 12.5 1 x 12.5 2 x 11 2 x 11
1.25 / 4 / 14 1.25 / 4 / 14 1.7 / 4 / 14 1.7 / 4 / 14
2.2 / 3 / 16 2.2 / 3 / 16 3.6 / 3 / 16 3.6 / 3 / 16
Application Guide BALTIC - 0108 • 19 •
GENERAL DATA
BAC = Cooling only rooftop BAH = Heat pump rooftop BAG =CoolingonlywithgasredheatingBAM=Heatpumprooftopwithgasredheating
Table 1.1
Size Size
NominalAirow
Cooling BAC-BAG
GrossCoolingcapacity(1)
Net Cooling capacity
Power input BAC
Full load amps
Direct start up amps ratio Id / Ia
COPgrossBAC(3)
COPnetglobalBAC(2)
Cooling BAH-BAM
GrossCoolingcapacity(1)
Net Cooling capacity
Power input BAH
COPgrossBAH(3)
COPnetglobalBAH(2)
Heating BAH-BAM
Netheatingcapacity(1)
GrossHeatingcapacity(1)
Power input BAH
COPgrossBAH(3)
COPnetglobalBAH(2)
Part Load BAH-BAM (11)
PARTLoad%
Gross Cooling capacity in PART LOAD
Power input BAC in PART LOAD
COP gross cooling at part load
Heating - gaz red
Heating capacity
Input(stdheat/highheat)
Thermalefciency
GAZow(fornaturalgazat20mbarand15°C)
Refrigeration circuit
Nb of Circuits x Compressor type nb x type
TANDEM TANDEM DUAL DUAL
Expansion nb x type
Refrigerant charge per circuit Clim / PAC
Coils
Indoor Coil : Face area / nb of rows / Fin per inch m2 / nb / FPI
Outdoor Coil : Face area / nb of rows / Fin per inch m2 / nb / FPI
(1)AlldataareatEuroventconditionat400V/3Ph/50Hz.
Summer : Outdoor temperature 35°C DB / Entering coil temperature
27°CDB/19°CWB.(2)excludingheatingemissionofthesupplymotorfan.(3)includingheatingemissionofthesupplymotor
fan. Winter:Outdoortemperature7°CDB,6°CWBEnteringcoiltemperature20°CDB.(4)AtnominalAirow.(5)S=Small,H
=Hight.(6)atdownreturnairanddownsupplyairconguration.(7)belowthisvalue,option"Lowambiantkit"isrequired