Specifications

SECTION 3 - MAINTENANCE AND CLEANING
The ECONOBURN™ Wood-Fired Boiler must be cleaned regularly to maintain top efficiency. A
good practice is to establish a routine for the storage of fuel, care of the appliance, and firing tech
-
niques.
BOILER MAINTENANCE
TURBULATOR ARMS AND SHAFT SHOULD BE CLEANED EVERY 3 DAYS OF BOILER
USAGE WHEN THE UNIT IS HOT.
ASHES SHOULD BE REMOVED AS NEEDED.
CLEAN HEAT EXCHANGERS ANNUALLY WITH A 2 INCH BORE BRUSH OR SIMILAR
DEVICE.
INSPECT REFRACTORY AND NOZZLES EVERY 6 MONTHS TO CHECK CONDITION.
TURBULATOR CLEANING
Every 3 days of boiler use, the Turbulator Arms and Shaft should be cleaned. To perform this
maintenance, grasp the Turbulator Agitation Lever on the upper left side of the boiler (Figs. 11 &
12), and firmly raise and lower it several times. The turbulator arm will only move a short distance
back and forth, and should be left as shown in Fig. 12.
When this lever is shaken back and forth, it clears the Turbulator Arms and Shaft of any buildup of
soot and ash that might have collected from the normal functioning of the boiler combustion.
1)
2)
3)
4)
Figure 11
Figure 12
24