Step C: Install RO Filter Assembly
9''
FIG. 13
S
crew (2)
15-1/2'' minimum up
from floor. This allows
space to remove and
change filters
Hanger
Washer (2)
Step D - Install Storage Tank
FIG. 14
Tank
Nipple
Storage
Tank
Tubing Nut
Tubing Insert
Tubing Connector
The fitting on the supply tank may need to be tight-
ened 7-8 full turns to get a good seal.
Do not overtighten.
INSTALL STORAGE TANK
1. Apply thread sealing tape (2 wraps clockwise) to
the threads on the nipple at the top of the tank. See
Fig 14.
2. Locate the tubing connector. See Fig. 14. Tighten
the tubing connector onto the tank nipple 7-8 full
turns, being careful not to cross thread or overtighten.
3. Do not connect the tube at this time. This will occur
later in the assembly.
4. Place the storage tank next to the Reverse Osmosis
Assembly. The tank can be placed upright or on its
side.
INSTALL REVERSE OSMOSIS FILTER
ASSEMBLY
T
he Reverse Osmosis Filter Assembly is mounted on
hanger washers.
See Fig 13. The hanger washers allow you to lift the
filter assembly from the washers without any hardware
removal. When planning your installation, you need to
leave room for changing filters.
Complete the following steps to install your Reverse
Osmosis Filter Assembly:
1. Remove the cover.
2. Locate mounting slots on back inside of the assem-
bly. See Fig 13.
3. Hold the assembly up to the wall surface and mark
locations for the hanger washers. See Fig 13. Mount
the unit high enough to allow room to change filters
without taking the unit off of the wall.
4. Fasten the hanger washers to the wall using the
screws provided.
5. Hang assembly on washers.
6. Replace cover.