Flair ™ OWNER’S MANUAL • Application ����� • Noteable Features • Specifications • Installation • Operation • Maintenance • Warranty Living Air Electronic Air Purification Systems 100, 110, 220/240 volt Flair™ Systems EcoQuest International® 310 T. Elmer Cox Drive • Greeneville, TN 37743 • 423.638.7246 www.EcoQuest.com CAUTION: read manual carefully for proper procedures and operation.
CONTENTS Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Notable Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Model Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Principles of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Applications Eliminate • Smoke • Odors • Tobacco Smoke Plus it works as an appliance to Sanitize an area to Reduce • Mold • Mildew • Bacteria Notable Features • Compact • Portable • No Duct Work Required • No Chemicals • Low Maintenance • Low Electrical Use • Complete User Control • No Residual Contamination • Plugs into 100, 110 (220 - 240) volt outlet Flair Specifications • Positive/Negative Ion Generation Technology • Ozone Generation Features: • Adjustable Fan Speed Control • Sanitization
PRINCIPLES OF OPERATION Nature cleanses the air with the lightning and rain. Lightning bolts produce ozone, as well as positive and negative ions which cleanse the air naturally. Rain helps bring the ozone and ions closer to the earth's surface. They are then attracted to atmospheric contaminants that are either removed from the air and attached to grounded objects or are oxidized. The Flair reproduces the natural conditions found in the outdoors. It is not designed to create an artificial environment.
2 Screws (220 & 240 volt only) 1 2 3 SYNAIRGTM PURIFICATION PLATE INSTALLATION a The Flair utilizes two SynAirGTM purification plates. 1. Remove (2) phillips-head screws. (220/240 volt only) b 2. Remove the rear lint screen. 3. Fully insert the SynAirGTM purification plates (A & B) between the guides until they stop. 4. Re-install lint screen as shown below. NOTE: The Flair’s SynAirGTM purification plates should only be used in the Flair system.
PLACING THE UNIT Place the unit as high as possible for maximum effectiveness. ����� (On top of a bookshelf, high cabinet, etc. An attractive wall-mounted bracket is also available - see figure A) If raised placement is not available, place unit as high as possible and elevate front of unit so fan blows towards ceiling. Pollutants such as smoke may rise and, when elevated, the unit can oxidize the pollutants more effectively. A ceiling fan can also aid in distribution of cleansing properties.
SETTING AND ADJUSTING CONTROLS 1. FAN CONTROL The disbursement of cleansing properties is best accomplished with good air circulation. The fan control should be set as high as possible without creating an undesirable noise level. This will be determined by personal preference and the distance you wish the cleansing properties to be dispersed. Note: A ceiling fan can also aid in distribution of cleansing properties. 2. OZONE CONTROL Ozone Control: Set the control at the nine o'clock position for one hour.
MAINTENANCE Periodic maintenance is required to insure that the Flair operates properly. A severely polluted environment can foul an SynAirGTM purification plate in as little as two weeks or as long as a year. Shown here are basic maintenance procedures that should be carried out to keep your unit running at top performance.
Removing the Chassis & Changing the Fuse: CAUTION: Unplug unit from AC outlet A) Remove the chassis from the cabinet by first removing the screw on the bottom of the cabinet. A B) Slide the chassis out and place it on its side. C) The fuse holder is located on the right front side of the circuit board. D) Simply remove the fuse by gently pulling it from the fuse holder. E) Replace with a slow blow type fuse*. B F) Re-assemble in reverse order. C *100, 110 volt models - use 1.0 Amp slow blow fuse.
Troubleshooting - What to look for first. 1. I have plugged in the unit, turned "ON" the power switch and nothing happens…what's wrong? • Make sure the electrical outlet is working properly. • Check the lint screen located at the back to ensure that the safety switch activator clip depresses the safety switch. • Check to see if the proper fuse is installed and that it is operational. 2.
5. What are the most typical application problems? • Symptom: A belief that the proper equipment is placed in the environment and the equipment appears unsuccessful. Problem: Lack of air movement, improper placement of the unit. • Symptom: Strong odors still remain with the environment after placement. Problem: Lack of ozone, improper placement of the unit. • Symptom: A strong odor of ozone is present within the environment.
WARRANTY INFORMATION This product is of solid state construction and is warrantied by EcoQuest International 310 T. Elmer Cox Drive Greeneville, TN 37743 to the original purchaser, depending on model, to be free from defect in materials and workmanship for a limited time. Length of warranty will vary depending on model. See warranty card for specific details. If you have any questions concerning your Living Air system, please see your local EcoQuest Dealer.