INSTALLATION, OPERATION AND MAINTENANCE MANUAL Please read these instructions completely before operating the EcoSmart™ Fire.
ENGLISH Testing and Compliance Statement The EcoSmart™ Fire Collection has achieved Swedish Institute for Technical Approval in Construction (SITAC) approval. EcoSmart Fire is TÜV certified in Germany when using Burner Two within a Firebox setting. For further information, please contact your distributor.
Contents ENGLISH Contents Conditions of Use 2 3 Warnings 3 4 Standard Equipment Received Clearances & Installation Ventilation & Efficiency 5-4 6 7 - 10 11 - 12 9 How to operate the EcoSmart™ Fire 10 13 Purchasing your Denatured Ethanol* 13 Decanting your Denatured Ethanol* into the Jerry Can 13 Volume markings on the EcoSmart™ Burner – Slider position markings 14 X Decanting the fuel from the Jerry Can into the EcoSmart™ Burner 15 Lighting the EcoSmart™ Burner 16 X Regulating the fla
ENGLISH Conditions of Use Conditions of Use Congratulations on your purchase of the EcoSmart™ Fire. The Fire Company Pty Ltd is very safety conscious. We have taken every care in designing, manufacturing and assembling your EcoSmart™ Fire to ensure it operates effectively, efficiently, and safely. In return, we ask that you exercise care when using this product and follow the instructions below: 1.
Warnings Warnings ENGLISH 1. Risk of explosion: a) Never use any fuel other than the fuels specifically identified for use in the appliance. Never use gasoline. b) Never fill the fuel reservoir when it is operating or still hot. c) Never fill fuel reservoir in areas where flammable vapours or gas may be present. d) Never store or transport the fuel in other than a metal or plastic container that is: 1. Acceptable for use with the specific fuel. 2.
ENGLISH Standard Equipment Received Standard Equipment Received Please ensure that all items have been received. The Burner Kit includes the minimum equipment required to operate the EcoSmart™ Fire safely.
Standard Equipment Received ENGLISH Top Tray All EcoSmart™ Burners must incorporate a protective “Twin Skin” into their setting. Off the shelf models from the Designer Range, Renovator Range and Grate Range include a built in “Twin Skin” and therefore will not include a Top Tray as an accessory. (NOTE: Not applicable for the Around Burner.) INSTALLATION, OPERATION AND MAINTENANCE MANUAL Burner Kits Burner One Top Tray h 114mm x w 320mm x d 320mm h [4.5in] x w [12.6in] x d [12.
ENGLISH Clearances & Installation Clearances & Installation The installation & clearances guidelines below are provided as a general overview only. Detailed installation specifications are available for each individual model of the EcoSmart™ Fire range and should have been referred to and taken into account prior to your purchase.
Clearances & Installation ENGLISH INSERTING WITHOUT A FIREBOX SETTING: When creating a custom built setting the following dimensions must be adhered to at all times. Burner Kits Overhead Rear Front Sides Metric mm Imperial [in] Metric mm Imperial [in] Metric mm Imperial [in] Metric mm Imperial [in] Nearest Combustible Radius Metric mm Imperial [in] Burner One & Burner Two 1500 [59.1] 30 [1.2] 45 [1.8] 600 [23.6] 600 [23.6] XL Burner 1500 [59.1] 40 [1.6] 65 [2.6] 600 [23.6] 600 [23.
ENGLISH Clearances & Installation Installation Requirements There are many different variations available for installing the EcoSmart™ Burner.
Clearances & Installation ENGLISH Top Tray The incorporation of a Top Tray (“Twin Skin”) into your setting protects against heat transference and aids in the collection of any accidental spillage. If utilising one that is not supplied by The Fire Company Pty Ltd then it must undergo a “water tight” test prior to inserting the EcoSmart™ Burner into place.
ENGLISH Ventilation & Efficiency Ventilation & Efficiency Ventilation EcoSmart™ Fires do not require any form of permanent fixture or fitting, such as a flue for ventilation, a permanent connection or any kind of fixed utility for fuel supply. Denatured Ethanol* is safe to burn indoors without venting, because its main by-products are carbon dioxide, water steam and heat.
Ventilation & Efficiency ENGLISH Efficiency The EcoSmart™ Fire is efficient because it is flueless which means all the heat stays in the room rather than most of it being flued outside as residual emissions. You can turn the Burner on and off as desired. You can control the intensity of the flame through its regulatory mechanism. XL Burner: Not applicable. Around Burner: Four (4) clip-on baffles are included with the Around Burner.
ENGLISH How to operate the EcoSmart™ Fire How to operate the EcoSmart™ Fire It is important that you follow the procedures outlined below to ensure that you are operating and utilising the EcoSmart™ Fire safely. Purchasing your Denatured Ethanol* Again for the purposes of this manual we refer to the fuel used in the EcoSmart™ Fire as Denatured Ethanol*. *There are many different names for this fuel around the world. Please refer to www.ecosmartfire.
How to operate the EcoSmart™ Fire ENGLISH Volume Markings – Slider Position Markings The Fire Company Pty Ltd recommends that the quantity of Denatured Ethanol poured into the burner be burnt until empty rather than extinguishing the fire early. Extinguishing the fire early will result in a larger amount of residual fumes in the EcoSmart™ Burner and a more volatile re-ignition. XL Burner: For optimum flame visibility the XL Burner should be filled to the max 10Lt point each time the burner is operated.
ENGLISH How to operate the EcoSmart™ Fire Decanting the fuel from the Jerry Can into the EcoSmart™ Burner. When filling the EcoSmart™ Burner, only fill through the designated filling point. The EcoSmart™ Burner must be at room temperature. 1. Position the slider mechanism setting so the chamber is fully open. 2 2. Inspect burner to ensure it is clean and clear of any foreign particles. 1 3 3.
How to operate the EcoSmart™ Fire ENGLISH Lighting the EcoSmart™ Burner Keep hands and face well away from the EcoSmart™ Fire at all times, particularly when igniting. 2 1 Before lighting, ensure that the EcoSmart™ Burner is clear and ready for use. When lighting the EcoSmart™ Burner the slider must be positioned at max to allow for correct ventilation. 1. Dip the lighting rod tip into the chamber opening “Burner zone” to wet the end. 2.
ENGLISH How to operate the EcoSmart™ Fire Re-igniting the EcoSmart™ Fire 1. Check that the Burner is at room temperature. If not, wait until the Burner has cooled. As a guide, it will take approximately 15 to 30 minutes depending on when and for how long it was last operated. 2. Move the slider/hinge so Burner opening is fully open. 3.
Maintenance Instructions Maintenance Instructions ENGLISH Maintenance and cleaning must only be performed when the EcoSmart™ Burner is OFF, COMPLETELY EMPTY & DRY and at ROOM TEMPERATURE. Over time, a film of black residue will apear on the 2 vents inside the burner and around the burning zone on the burner top. If service is required, there are two specific areas to check for cleaning. These are the EcoSmart™ Burner and the Firebox or immediate surrounds in cases where a firebox has not been installed.
ENGLISH Troubleshooting Troubleshooting Some troubleshooting procedures should only be carried out by qualified technicians. 1. a. b. c. d. There is smoke or a foreign smell coming from the burner when burning There may be waste burning that should not be in the burner. You are using the wrong fuel (It is imperative that you ONLY use Denatured Ethanol*). You have placed something around/above the flame that has not been approved or recommended.
Your Warranty Your Warranty ENGLISH Your EcoSmart™ Fire is covered by a transferable limited warranty and a solid service and support network should you need it. At The Fire Company Pty Ltd, we believe in supplying you with the best, most user friendly fireplace and providing you with the means to keep it that way. Many aspects of the EcoSmart™ Fire are handproduced, hand-finished and use natural materials, which makes them subject to minor variations in finish and size.
ENGLISH After Sales Service After Sales Service It is our aim for you to be totally satisfied with your EcoSmart™ Fire product. If you need service or assistance, we suggest you follow these steps. After Sales Service for your EcoSmart™ Fire The Fire Company Pty Ltd offers an international network of authorised service agents. The use of other than approved EcoSmart™ Fire parts and accessories may damage or reduce the performance of your EcoSmart™ Fire and may also endanger the user.
www.ecosmartfire.
The EcoSmart™ Fire is designed and manufactured by The Fire Company Pty Ltd whose quality management system is certified as being in conformity with ISO 9001:2000. REV0709 Visit www.ecosmartfire.com to find a complete list of distributors and retail stores. DNV Certification Pty Ltd 10 Apollo Street, Warriewood NSW 2102, Australia T: +61 2 9997 3050 F: +61 2 9997 6050 E: info@thefirecompany.com.