1
2
Lighting the EcoSmart™ Burner
Keep hands and face well away from the EcoSmart™ Fire at all times, particularly when igniting.
Before lighting, ensure that the EcoSmart™ Burner is clear and ready for use. When lighting the
EcoSmart™ Burner the slider must be positioned at max to allow for correct ventilation.
1. Dip the lighting rod tip into the chamber opening “Burner zone” to wet the end.
2. Lift the lighting rod away from the Burner (do not drip fuel on the floor).
3. Ignite the lighter and make contact with the lighting rod as if lighting a candle.
4. Dip the ignited lighting rod back into the Burner zone to ignite the contained fuel.
NOTE: The XL Burner is best ignited from the right hand side of the ignition zone.
Once lit there will be a residual flame on the lighting rod that must burn out before putting the rod away. If the
flame on the lighting rod dies before reaching the burner, repeat the procedure until successful.
Due to the natural oils in the fibres we use in the EcoSmart™ Burner there is a stronger than usual smell when
first operating. It will decrease substantially after the first few times you use the Burner, and even more so over
time.
3
4
Regulating the flame
Wait until the fire is established (approx 10 minutes) before regulating.
To decrease the flame intensity insert the lighting rod tip through the circular ring and push forward gently
to desired setting.
To increase the flame intensity insert the lighting rod tip through the circular ring and pull back gently to
desired setting.
XL Burner: Feature not available in XL Burner.
Around Burner: Four (4) clip-on baffles are included with the Around Burner. The clip-on baffles allow you
to control the amount of heat being generated and the quantity of Denatured Ethanol*
used. (NOTE: Clip-on baffles must be positioned before operating the Burner)
Turning your EcoSmart™ Fire Off - Extinguishing the flame
Insert the lighting rod tip through the circular ring and push forward firmly until completely closed and
in the OFF position. If you do not burn the Denatured Ethanol* until empty then you must not add more
Denatured Ethanol* to the Burner OR re-ignite the burner until it has cooled to room temperature. When
there is no more fuel, the fire will go out with nothing to clear or clean ready to be re-started when cooled.
XL Burner: The XL Burner has a Flip Lid shut off system. The lid flips across the ignition zone which
extinguishes the flame.