MSDS
_____________________________________________________________________________________________
1174174 - R40 CFL Light Bulb
Revision Date 15-Aug-2014
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Solders, dross - Oxides formed during the
melting and use of solders for the
electronics industry. Consists primarily of
oxides of tin, lead and antimony with some
silver and gold.
94551-97-0
TWA: 2 mg/m
3
Sn except Tin
hydride TWA: 0.05 mg/m
3
Pb
TWA: 0.5 mg/m
3
Sb
TWA: 2 mg/m
3
Sn except oxides
TWA: 50 µg/m
3
Pb TWA: 0.5
mg/m
3
Sb
Action Level: 30 µg/m
3
Pb
Poison, See 29 CFR 1910.1025
(vacated) TWA: 2 mg/m
3
Sn
except oxides (vacated) TWA: 0.5
mg/m
3
Sb
IDLH: 100 mg/m
3
Sn
IDLH: 50 mg/m
3
Sb
IDLH: 100 mg/m
3
Pb
TWA: 2 mg/m
3
except Tin oxides
Sn
TWA: 0.5 mg/m
3
Sb
TWA: 0.050 mg/m
3
Pb
Yttrium
7440-65-5
TWA: 1 mg/m
3
TWA: 1 mg/m
3
Y TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 500 mg/m
3
TWA: 1 mg/m
3
Barium oxide
1304-28-5
TWA: 0.5 mg/m
3
Ba TWA: 0.5 mg/m
3
Ba
(vacated) TWA: 0.5 mg/m
3
Ba
TWA: 0.5 mg/m
3
except Barium
sulfate Ba
Silicon
7440-21-3
- TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
(vacated) TWA: 10 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable fraction
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
Zinc
7440-66-6
STEL: 10 mg/m
3
respirable
fraction
TWA: 2 mg/m
3
respirable fraction
TWA: 5 mg/m
3
fume
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
IDLH: 500 mg/m
3
Ceiling: 15 mg/m
3
dust
TWA: 5 mg/m
3
dust and fume
STEL: 10 mg/m
3
fume
Nickel
7440-02-0
TWA: 1.5 mg/m
3
TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 10 mg/m
3
TWA: 0.015 mg/m
3
Copper
7440-50-8
TWA: 0.2 mg/m
3
fume TWA: 1
mg/m
3
Cu dust and mist
TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu
dust, fume, mist
IDLH: 100 mg/m
3
dust, fume and
mist
TWA: 1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume
Aluminum
7429-90-5
TWA: 1 mg/m
3
respirable fraction TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
(vacated) TWA: 15 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable fraction (vacated)
TWA: 5 mg/m
3
Al Aluminum
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
7. HANDLING AND STORAGE
Precautions for safe handling
Handling
In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. Ensure adequate ventilation. In case of insufficient
ventilation, wear suitable respiratory equipment. Do not eat, drink or smoke when using this
product. Take off contaminated clothing and wash before reuse. Do not breathe dust. Avoid
generation of dust.
_____________________________________________________________________________________________
Conditions for safe storage, including any incompatibilities
Storage
Page 5 / 12
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep out of the reach
of children. Store locked up.
Incompatible Products
None known based on information supplied.