5.6 Electrical Performance 电性能测试
5.6.1 Temperature Dependence of Capacity (Discharge) 不同温度放电容量
Cells shall meet the discharge capacity requirements listed in the below table under respective discharge
temperatures. The capacities are to be measured with constant discharge current 0.5CmA (2.75V cut-off)
after standard charge at 25±2.
电池芯在 25±2电后,然后在 30 钟内热到,下保 1 小时,再以
0.5CmA 进行放电测试.
Discharge Temperature
放电温度
-20
0
25
60
Discharge Capacity
放电容量
50%
85%
100%
95%
5.6.2 Cycle Life 循环寿命
10min rest period after standard charge, 0.5C discharge to a cut-off voltage of 3.0V, 10min rest period, the
capacity shall be measured after 500 cycles of standard charge and discharge at 25±5.
25±5环境温度下,电池标准充电后,搁置 10 分钟, 0.5C 将电池放电至 3.0V,每次充放电间隔 10 分钟,
重复上述步骤,进行循环 500 .
Capacity 80%
容量 初始容量的80%
5.6.3 Shelf Life 荷电保持能力
Item 项目
Measuring Procedure 测试条件
Requirements 备注
Storage
Characteristics 1
储存性能 1
1
The capacity on 1.0CmA discharge shall be
measured after standard charge and then storage
at 25±2 for 28 days.
采用标准充电, 25±2℃下储 28 天后以 1.0CmA
放电对电池进行容量测试。
Remaining Capacity
容量保持85% C5
2
After above measured Remaining capacity, the
capacity on standard discharge shall be measured
after standard charge.
以上测量后剩余容量,采用标准充电,并对标准放电
下的电池进行容量测试。
Recovery capacity
恢复容量90% C5
Storage
Characteristics 2
储存性能 2
1
The capacity on 0.5CmA discharge shall be
measured after standard charge and then storage
at 60 for 30 days.
采用标准充电,在 60℃下储存 30 天后以 0.5CmA
放电对电池进行容量测试。
Remaining Capacity
容量保持75% C5